{"product_id":"is200staih2a-ge-mark-vi-20-channel-analog-terminal-board","title":"IS200STAIH2A GE Mark VI 20-Channel Analog Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200STAIH2A (including revision IS200STAIH2ACB) functions as a high-density Simplex Analog Input Terminal Board within the Mark VI Speedtronic control architecture. This module provides the critical hardware interface for up to 20 field analog signals, including 4-20 mA current loops and ±5 V DC inputs. By consolidating inputs from temperature, pressure, and flow transmitters into a single hardened interface, the IS200STAIH2A ensures the turbine control processor receives precise, noise-filtered data for real-time decision-making. We deliver this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New in Box (NIB)\u003c\/strong\u003e, guaranteeing factory-original calibration and component integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200STAIH2A utilizes professional-grade galvanic isolation and surge protection to maintain signal purity in high-EMF power plant environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200STAIH2A \/ IS200STAIH2ACB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Mark VI Turbine Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Analog Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA current loop, ±5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower-to-signal and Channel-to-channel Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5%–95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Mark VI board (30 × 20 × 5 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEMI Shielding, Integrated Surge Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Consolidation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200STAIH2A supports 20 independent analog channels on a single board. This high density reduces the number of terminal blocks required in the control cabinet, saving valuable panel space and simplifying cable management for complex turbine subsystems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board features comprehensive isolation barriers between power and signal circuits. This design prevents ground loops and electrical transients from damaging the central Mark VI processor, ensuring the safety of the entire Distributed Control System (DCS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineered the IS200STAIH2A with robust EMI shielding. This prevents high-frequency interference from nearby motors or switchgear from distorting sensitive analog signals, maintaining the high precision required for process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance Workflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular, hot-swappable design allows for rapid hardware replacement. Technicians swap the board without de-energizing the entire control rack, which prevents unnecessary turbine trips and significantly lowers the Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand the thermal stresses of power generation facilities, the board maintains accuracy from -20°C to +65°C. The robust construction resists vibration and dust, ensuring long-term reliability in non-climate-controlled instrument rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the IS200STAIH2A and the \"H2ACB\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"H2ACB\" suffix indicates the specific hardware revision and assembly group. The IS200STAIH2ACB remains fully backward compatible with the base IS200STAIH2A model, providing the same form factor and electrical specifications for the Mark VI system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board support both current and voltage inputs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IS200STAIH2A handles both 4-20 mA current loops and ±5 V DC voltage signals. Engineers configure individual channels via the Mark VI software (ToolboxST) to match the specific requirements of the connected field transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board suitable for TMR (Triple Modular Redundant) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200STAIH2A is a \"Simplex\" terminal board, typically used in applications where a single interface is sufficient. For TMR configurations requiring triple redundancy, GE offers specific TAIH terminal boards designed for voting logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the board is 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery IS200STAIH2A we supply is New in Box (NIB), featuring the original manufacturer's seal and anti-static packaging. This ensures the board has never been installed or exposed to field contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44098863169635,"sku":"IS200STAIH2A","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/389._15478c4a-0622-4547-abdc-dd2657222432.jpg?v=1775205149","url":"https:\/\/www.autocontrolglobal.com\/products\/is200staih2a-ge-mark-vi-20-channel-analog-terminal-board","provider":"AutoControl Global","version":"1.0","type":"link"}