{"product_id":"is200tbcih1bbd-general-electric-mark-vi-terminal-board","title":"IS200TBCIH1BBD General Electric Mark VI Terminal Board","description":"\u003ch2\u003eGeneral Electric IS200TBCIH1BBD Mark VI Contact Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200TBCIH1BBD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TBCI\u003c\/strong\u003e Contact Input Terminal Board, operates as a dedicated hardware component for interfacing 24 dry contact discrete field inputs within GE Speedtronic Mark VI turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBCIH1BBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33.02 cm x 10.16 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 channels (dry contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Filter\u003c\/td\u003e\n\u003ctd\u003e4 ms filter delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V between field wiring and system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eBarrier terminal blocks and high-density connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\/Mounting\u003c\/td\u003e\n\u003ctd\u003eCabinet rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Backplane \u0026amp; Deterministic Networking\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200TBCIH1BBD\u003c\/strong\u003e processes discrete field signals and passes them across the high-speed Mark VI VMEbus system backplane. Hardware filters impose a fixed 4 ms delay to eliminate contact bounce from field switches prior to backplane transmission.\u003c\/p\u003e\n\u003cp\u003eThe board maintains fixed timing across deterministic control loops without introducing backplane communication latency. Onboard memory holds hardware identification, enabling strict firmware flash compatibility verification upon system power-up. Integrated surge protection and 1500 V electrical isolation safeguard central processing cards against field transients and ground potential differences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 4 ms hardware filter on the IS200TBCIH1BBD impact contact signal detection?\u003c\/p\u003e\n\u003cp\u003eA: The 4 ms hardware filter attenuates high-frequency noise and mechanical contact bounce on dry contact input lines, ensuring clean digital state changes reach the Mark VI processor without false triggering.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200TBCIH1BBD card be removed or replaced while system backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swapping is prohibited. Technicians must completely de-energize cabinet power supplies before removing or replacing the board to prevent backplane signal corruption and voltage surges.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms protect internal processing logic against external field voltage transients?\u003c\/p\u003e\n\u003cp\u003eA: Integrated surge suppression networks combined with a 1500 V galvanic isolation barrier isolate discrete input terminal screw connections from the sensitive backplane control electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IS200TBCIH1BBD card securely into the designated Mark VI VME rack slot using metal fasteners to establish chassis ground continuity. Verify that cabinet operating ambient temperatures stay within the specified -30 deg C to +65 deg C range.\u003c\/p\u003e\n\u003cp\u003eConnect dry contact field wiring directly to the terminal barrier blocks, ensuring screw terminals are torqued properly to maintain reliable low-resistance connections. Route discrete input cables separately from high-voltage power conduits to limit inductive coupling. Ensure system backplane power is fully isolated before connecting or removing signal lines.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44442552467555,"sku":"IS200TBCIH1BBD","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/446._f867326c-a3d8-4553-a87f-671d5030af5f.jpg?v=1785911357","url":"https:\/\/www.autocontrolglobal.com\/products\/is200tbcih1bbd-general-electric-mark-vi-terminal-board","provider":"AutoControl Global","version":"1.0","type":"link"}