{"product_id":"is200trtdh1ci-ge-fanuc-mark-vie-rtd-input-module","title":"IS200TRTDH1CI GE Fanuc Mark VIe RTD Input Module","description":"\u003ch2\u003eGE Fanuc IS200TRTDH1CI Mark VIe RTD Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200TRTDH1CI\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRTDH1\u003c\/strong\u003e RTD Input Terminal Board, operates as a dedicated hardware component for signal acquisition and conditioning of temperature inputs within Mark VIe turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRTDH1CI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e178 mm x 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by I\/O core load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (3-wire RTD configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003ePT100 (standard), software configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connections\u003c\/td\u003e\n\u003ctd\u003eBarrier-type terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eDual 37-pin female D-sub connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Filtering\u003c\/td\u003e\n\u003ctd\u003eNoise suppression capacitor matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Connectivity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200TRTDH1CI\u003c\/strong\u003e digitizes analog resistance measurements from field-mounted temperature elements and transfers data frames through dual 37-pin cabling directly to the I\/O pack. Filtering capacitors across every channel suppress high-frequency noise and prevent signal distortion prior to analog-to-digital conversion.\u003c\/p\u003e\n\u003cp\u003eThe terminal board maintains firm hardware compatibility with Mark VIe I\/O core assemblies, utilizing onboard ID EEPROM circuits to verify firmware flash compatibility during controller startup sequences. Integrated surge protection networks safeguard central processing electronics from field-induced voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What sensor configurations does the IS200TRTDH1CI support on its field wiring terminals?\u003c\/p\u003e\n\u003cp\u003eA: The board accepts up to 16 3-wire RTD sensor inputs (standard PT100 elements), utilizing barrier terminal blocks to ensure solid conductor clamping and lead wire resistance compensation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IS200TRTDH1CI route processed temperature signals to the Mark VIe I\/O core?\u003c\/p\u003e\n\u003cp\u003eA: Temperature signals route through onboard signal conditioning circuitry directly to dual 37-pin female D-sub connectors, which mate with high-density system cables linked to the primary I\/O pack.\u003c\/p\u003e\n\u003cp\u003eQ: Are individual channels isolated from high-voltage system noise?\u003c\/p\u003e\n\u003cp\u003eA: Integrated filtering capacitor arrays and surge suppression components isolate individual RTD signal paths, suppressing electromagnetic interference before data enters the system bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IS200TRTDH1CI board onto the cabinet mounting rack using standard grounding hardware to ensure proper chassis Earth grounding. Maintain ambient enclosure temperatures within the 0 deg C to 60 deg C operating envelope.\u003c\/p\u003e\n\u003cp\u003eConnect 3-wire RTD conductors to the designated barrier screw terminals, torquing each connection firmly to prevent high-resistance signal faults. Route low-level RTD cables through grounded metal conduits separate from AC power lines. Confirm all 37-pin connector latching screws are fully seated before applying system power.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44442712637539,"sku":"IS200TRTDH1CI","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/414._0d5264f0-f908-4e56-a52f-ec3ed190e60f.jpg?v=1785914611","url":"https:\/\/www.autocontrolglobal.com\/products\/is200trtdh1ci-ge-fanuc-mark-vie-rtd-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}