{"product_id":"kj2003x1-pw1-emerson-deltav-redundant-terminal-block-original-stock","title":"KJ2003X1-PW1 Emerson DeltaV Redundant Terminal Block | Original Stock","description":"\u003ch1\u003eEmerson KJ2003X1-PW1 DeltaV SIS Series Redundant SLS Terminal Block\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ2003X1-PW1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ2003X1-PW1\u003c\/strong\u003e Redundant SLS Terminal Block, operates as a dedicated hardware component for field wiring termination and redundant signal routing within DeltaV SIS safety networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKJ2003X1-PW1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV \/ Ovation SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e85 x 100 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1.5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e12 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e10 A total (up to 2 A per channel capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eContact Resistance\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eLess than or equal to 20 mOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eGreater than or equal to 100 MOhm @ 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eSafety Integrity\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eIEC 61508 SIL 3 capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe redundant terminal block interfaces directly with the Smart Logic Solver (SLS) backplane to sustain dual-channel analog signal pass-through and digital I\/O processing. The mechanical tracking path preserves galvanic isolation barriers between parallel hardware channels, ensuring that high-frequency noise from a single 4-20 mA HART loop does not cause inductive interference on adjacent safety circuits. This isolation framework supports continuous monitoring of diagnostic data across field loops while routing critical signals to the redundant logic processing matrix without common-mode electrical hazards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the passive architecture of the KJ2003X1-PW1 handle hot-swap physical replacement?\u003c\/p\u003e\n\u003cp\u003eA: The terminal block supports online, live exchange capabilities where individual blocks are detached from the active SLS carrier board. Because the field terminals remain seated or unplugged via integrated modules, safety loops switch directly to the backup path without cutting power to the parallel infrastructure.\u003c\/p\u003e\n\u003cp\u003eQ: What are the integrated monitoring limits for diagnostic checks on this model?\u003c\/p\u003e\n\u003cp\u003eA: The terminal block acts as a passive termination interface. Line diagnostics, including open loop and short-circuit fault monitoring, are executed and registered directly by the active Smart Logic Solver modules attached to the backplane rather than the terminal block hardware itself.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the redundant SLS terminal block onto the specific carrier backplane slot, confirming that the card-edge contacts mate completely before applying electrical load.\u003c\/li\u003e\n\u003cli\u003eTerminate all field cables using the integrated screw or spring clamp terminals, maintaining uniform tension on all input wire configurations.\u003c\/li\u003e\n\u003cli\u003eRoute all critical emergency shutdown (ESD) and fire \u0026amp; gas analog lines through low-voltage cable trays separated from high-induction motor power wires.\u003c\/li\u003e\n\u003cli\u003eLand the instrumentation braided shielding wires directly onto the primary cabinet instrument earth ground bus rail to ensure optimal signal protection limits.\u003c\/li\u003e\n\u003cli\u003eMaintain the surrounding control panel environment below the 70 deg C ceiling to keep operating thermal gradients within calibrated manufacturer parameters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44211346341987,"sku":"KJ2003X1-PW1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/427._e698ec48-ec37-4472-8b0b-f2dd3bc14377.jpg?v=1779693069","url":"https:\/\/www.autocontrolglobal.com\/products\/kj2003x1-pw1-emerson-deltav-redundant-terminal-block-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}