{"product_id":"kj4006x1-bb1-emerson-terminal-block-datasheet-new-stock","title":"KJ4006X1-BB1 Emerson Terminal Block Datasheet | New Stock","description":"\u003ch1\u003eEmerson KJ4006X1-BB1 DeltaV M-Series\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ4006X1-BB1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ4006X1-BB1\u003c\/strong\u003e Analog Input Terminal Block, operates as a dedicated hardware component for field-wiring termination, signal routing, and electrical isolation interface within DeltaV M-Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKJ4006X1-BB1 (Alternative Reference: 12P4721)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.90 kg shipping weight \/ 0.10 kg nominal net weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e17.8 cm x 4.6 cm x 24.9 cm pack size \/ approx 125 x 41 x 105 mm module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003ePassive pass-through hardware; draws zero active backplane logic current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e8 input channels (24-point terminal matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e250 V AC\/DC (terminal hardware physical limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eMaximum Current Rating\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 A (terminal hardware structural maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eDeltaV M-Series I\/O carrier base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eScrew-clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eWire Size Accommodation\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eISA-S71.04 Class G3 compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eIP20 baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e10 g, 11 ms half-sine pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eMechanical Vibration\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e1 mm (2-13.2 Hz); 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eII 3G Ex ec IIC Gc; Class I Division 2 Groups A-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe terminal infrastructure provides a physical interface configured to route process data modulated over the 4-20 mA HART loop protocol. Galvanic isolation pathways integrated between the field-side terminals and the system-side backplane bus suppress high-voltage transients up to the 250 V structural boundary. Channel-to-channel isolation parameters are defined and enforced by the specific paired active M-Series I\/O card, isolating individual signal loops to prevent stray ground loop currents from interfering with parallel digital parameter synchronization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the defined physical hot-swap restrictions for this 24-point terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Online removal of the passive assembly block is restricted during operational processing. Hot-swapping must only occur when the associated active input card is unseated from the carrier slot and all 12 to 24 AWG field wiring connections have been entirely isolated and de-energized.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated rotary keying system enforce correct card alignment?\u003c\/p\u003e\n\u003cp\u003eA: The physical housing features an adjustable mechanical rotary key selector dial. This orientation prevents mechanical engagement with non-matching active cards, stopping users from plugging digital or non-compatible voltage modules into a terminal node wired for 4-20 mA analog circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLock the terminal block assembly firmly onto the designated M-Series I\/O carrier block, verifying that the backplane ground contacts seat flush against the rail.\u003c\/li\u003e\n\u003cli\u003eMatch the position code of the mechanical rotary keying system to the precise profile index of the assigned analog input card.\u003c\/li\u003e\n\u003cli\u003eStrip and land the 12 to 24 AWG signal wires into the screw-clamp terminal blocks, ensuring terminal screws are torqued to standard industrial ratings.\u003c\/li\u003e\n\u003cli\u003eLay all low-current 4-20 mA loops inside isolated wire ducts separated from three-phase AC power cables to mitigate high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eTerminate twisted-pair signal shield wires at a single ground reference point on the instrumentation copper grounding bar within the system panel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44212766441571,"sku":"KJ4006X1-BB1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/436._427d58bd-2603-48d1-b412-1ba513e77c7e.jpg?v=1779700314","url":"https:\/\/www.autocontrolglobal.com\/products\/kj4006x1-bb1-emerson-terminal-block-datasheet-new-stock","provider":"AutoControl Global","version":"1.0","type":"link"}