{"product_id":"kl3002x1-ba1-emerson-digital-output-charm-new-original-stock","title":"KL3002X1-BA1 Emerson Digital Output CHARM | New \u0026 Original Stock","description":"\u003ch2\u003eEmerson KL3002X1-BA1 SE4305T01 Series Module Type\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KL3002X1-BA1 SE4305T01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKL3002X1-BA1\u003c\/strong\u003e DO 24 VDC High-Side CHARM, operates as a dedicated hardware component for high-side switched 24 VDC digital output execution within Emerson DeltaV Electronic Marshalling platforms. The component mounts directly onto the CHARM I\/O baseplate structure, providing single-channel field device actuation loop management. By converting system backplane control bus instructions into a physical high-side solid-state switched path, this instrumentation module drives binary field loads independent of external mechanical marshalling terminals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL3002X1-BA1 SE4305T01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e454 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-channel CHARM form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower bus requirement of +6.3 VDC at 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eHigh-side switched discrete output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Loop Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Element\u003c\/td\u003e\n\u003ctd\u003eSolid-state high-side switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Field Loads\u003c\/td\u003e\n\u003ctd\u003eSolenoids, contactors, lamps, small actuators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Tolerance\u003c\/td\u003e\n\u003ctd\u003e1 mm (2 to 13.2 Hz), 0.7 g (13.2 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock Limit\u003c\/td\u003e\n\u003ctd\u003e10 g, 11 ms half-sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Ratings\u003c\/td\u003e\n\u003ctd\u003eZone 2 \/ Class I Div. 2 (ATEX, IECEx, UKEX, FM, UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe hardware infrastructure utilizes electronic marshalling parameters to enforce distinct electrical boundary security and noise suppression inside dense field enclosures.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Electrical Isolation:\u003c\/strong\u003e Electronic marshalling topology establishes high-dielectric galvanic isolation boundaries between individual CHARM slots. A fault or field short-circuit condition on one high-side output channel remains confined to that specific physical terminal block, protecting adjacent logic channels and host processor nodes from inductive damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Coexistence:\u003c\/strong\u003e The solid-state output switching circuitry is designed to limit electromagnetic interference (EMI) generations during contact transition phases. This fast edge-rate filtering prevents crosstalk or high-frequency harmonic injection into parallel multi-core field wire bundles carrying sensitive 4-20 mA HART loop protocol analog data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous State Diagnostics:\u003c\/strong\u003e The internal hardware diagnostic layer constantly evaluates loop current tracking. Real-time open-circuit and short-circuit conditions are identified and reported upstream via the localized power bus network, facilitating physical line validation during active commissioning sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the high-side configuration enhance safety when a field cable experiences a ground fault?\u003c\/p\u003e\n\u003cp\u003eA: In a high-side switching configuration, the module controls the positive leg of the 24 VDC loop while the field load remains continuously bound to the negative return rail. If the field cable inadvertently shorts to the chassis ground, the output current is cut off by the solid-state switch rather than causing an un-commanded, hazardous device activation.\u003c\/p\u003e\n\u003cp\u003eQ: Can an individual CHARM module be swapped out while the remaining baseplate channels are active?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware design allows single-channel hot-swap replacement. Technicians can unlatch and extract the target module from its baseplate slot without interrupting signal execution, power distribution, or data bus transactions on neighboring I\/O locations.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary structural requirements regarding environmental contamination?\u003c\/p\u003e\n\u003cp\u003eA: The module is certified to ISA-S71.04 Class G3 severity standards. This conformal coating protection layer allows the module to sustain continuous operations inside unconditioned field enclosures exposed to airborne corrosive contaminants and high humidity profiles without experiencing dendrite growth or parameter drift.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Alignment:\u003c\/strong\u003e Align the rear-side multi-pin plug of the CHARM module with the target slot on the standard electronic marshalling baseplate module. Push the component downward perpendicular to the DIN rail plane until the structural side latches snap into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Conductor Termination:\u003c\/strong\u003e Secure the field actuator wires to the dedicated terminal blocks allocated beneath the CHARM structure. Strip the wire insulation jacket to factory specifications, ensuring all copper strands are compressed cleanly within the screwless clamp terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Grounding:\u003c\/strong\u003e Verify the DIN rail system achieves low-impedance bonding with the enclosure frame and the master plant safety earth network. Compliance with Zone 2 and Class I Division 2 layout regulations requires all mechanical earth connections to be verified prior to energizing the 24 VDC external loop supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Dissipation Boundary:\u003c\/strong\u003e Maintain unrestricted convective air movement across the outer surface vents of the CHARM cluster assembly. Maintain local panel parameters so that the internal micro-climate boundaries do not exceed the designated -40 to +70 deg C operational threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43840397049955,"sku":"SE4305T01 KL3002X1-BA1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/95.2_bfd2d94b-798a-44a3-8e99-83c5f366ea2c.jpg?v=1763342941","url":"https:\/\/www.autocontrolglobal.com\/products\/kl3002x1-ba1-emerson-digital-output-charm-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}