{"product_id":"kl4104x1-ba1-emerson-deltav-carrier-datasheet-technical-manual","title":"KL4104X1-BA1 Emerson DeltaV Carrier Datasheet \u0026 Technical Manual","description":"\u003ch1\u003eEmerson KL4104X1-BA1 DeltaV Electronic Marshalling Series\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KL4104X1-BA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKL4104X1-BA1\u003c\/strong\u003e Dual Universal Carrier, operates as a dedicated hardware component for physical mounting and bus routing of CHARM modules within DeltaV Distributed Control System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eKL4104X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4.3 cm x 12.6 cm x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eRedundant +24 VDC power input distribution capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBase Architecture\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eDual universal carrier slot format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eTarget Modules\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eDeltaV CHARM I\/O modules, power units, and control nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eHazardous Certification\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eATEX Zone 2 compliant engineering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe dual universal carrier establishes the structural and electrical backbone for DeltaV Electronic Marshalling systems. The circuit pathways within the carrier plate maintain individual channel-to-channel isolation parameters between installed CHARM components, eliminating signal loop crosstalk and grounding offsets. The physical bus structure directly accommodates the 4-20 mA HART loop protocol by distributing clean, unattenuated DC excitation lines to individual signal conditioning keys, allowing continuous pass-through of high-frequency digital telemetry from field instruments to upstream controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the KL4104X1-BA1 respond to a primary electrical fault across its redundant power lines?\u003c\/p\u003e\n\u003cp\u003eA: The carrier structure contains dual parallel +24 VDC bus rails. If the primary power circuit suffers a voltage failure, the parallel circuit maintains uninterrupted distribution across the active I\/O slots without resetting the module power rails.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping of plugged CHARM units permitted on this base under live operating conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the mechanical and electrical mating design of the carrier supports live, slot-level insertion and removal of component hardware, provided the environmental area is non-hazardous or the specific field wiring meets intrinsic safety guidelines during the swap procedure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the universal carrier securely on standard 35 mm DIN rails inside the Marshalling enclosure, verifying alignment with sequential carrier expansion hooks.\u003c\/li\u003e\n\u003cli\u003eConnect the redundant +24 VDC supply lines using separated wire bundles from distinct, decoupled industrial power supplies.\u003c\/li\u003e\n\u003cli\u003eRoute all 4-20 mA field instrumentation lines through dedicated terminal channels, securing single-point shield terminations at the primary instrument earth bus bar.\u003c\/li\u003e\n\u003cli\u003eVerify the environmental enclosure meets the technical requirements for ATEX Zone 2 when operating the carrier in hazardous locations.\u003c\/li\u003e\n\u003cli\u003ePrevent physical blocking of the vertical ventilation clearances around the carrier base to remain within the continuous -40 to +70 deg C temperature parameters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44211345227875,"sku":"KL4104X1-BA1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/2.1_fc888c0f-422f-4908-b431-70e121e127e1.jpg?v=1779692732","url":"https:\/\/www.autocontrolglobal.com\/products\/kl4104x1-ba1-emerson-deltav-carrier-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}