{"product_id":"machine-edition-communication-modules-ge-fanuc-me98mbp001","title":"Machine Edition Communication Modules | GE Fanuc ME98MBP001","description":"\u003ch2\u003eGE Fanuc ME98MBP001 Machine Edition Communication Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc ME98MBP001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eME98MBP001\u003c\/strong\u003e PLC Communications Module, operates as a dedicated hardware component for Modbus TCP\/IP network integration and signal acquisition within industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eME98MBP001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 80 mm x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC auxiliary power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input Capacity\u003c\/td\u003e\n\u003ctd\u003e4 Digital Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Standards\u003c\/td\u003e\n\u003ctd\u003ePROFINET GSDML schemas (versions 2.34, 2.35, and 2.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe ME98MBP001 utilizes internal backplane bus architecture to manage data exchange with the primary controller, maintaining low-latency throughput for real-time monitoring tasks. In systems utilizing Machine Edition V9.8 and higher, the module supports advanced firmware features including EGD production on redundant IP for CPE400\/CPL410 Ethernet nodes. The hardware logic adheres strictly to PROFINET GSDML schemas, ensuring firmware flash compatibility, consistent protocol handling, and deterministic network behavior across complex industrial topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping during active network communication? A: Hot-swapping should only be performed if the specific rack configuration supports live module insertion. Always verify that the I\/O bus is de-energized or inhibited via the software controller prior to removal to prevent memory corruption or communication faults.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of the PROFINET GSDML schema support on existing system configurations? A: Support for GSDML versions 2.34 through 2.4 allows access to expanded diagnostic data fields. Users updating their software environment must ensure that master configuration files are updated in the Machine Edition project to acknowledge these system variables.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure stable mechanical mounting and reliable communication across industrial networks, follow these field installation steps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module directly onto the designated DIN-rail or rack slot, engaging the locking mechanism completely to prevent vibration decoupling.\u003c\/li\u003e\n\u003cli\u003eTerminate the external 24 VDC power supply lines to the module power terminals, verifying that voltage regulation remains within tolerance to protect internal communication circuitry.\u003c\/li\u003e\n\u003cli\u003eConnect all network drops using shielded twisted-pair (STP) Ethernet cabling to minimize signal degradation and electromagnetic noise interference.\u003c\/li\u003e\n\u003cli\u003eConnect the mounting plate or DIN-rail directly to cabinet structural ground to maintain electromagnetic compatibility and earth grounding protection.\u003c\/li\u003e\n\u003cli\u003eInspect local diagnostic LED status lights and confirm proper network handshaking via the Machine Edition hardware configuration utility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872808403043,"sku":"ME98MBP001","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/368_74071869-a790-4388-b63a-2b43de463261.jpg?v=1764921365","url":"https:\/\/www.autocontrolglobal.com\/products\/machine-edition-communication-modules-ge-fanuc-me98mbp001","provider":"AutoControl Global","version":"1.0","type":"link"}