{"product_id":"mark-v-lan-communications-card-ge-ds200slccg3ahd","title":"Mark V LAN Communications Card GE DS200SLCCG3AHD","description":"\u003ch2\u003eGE DS200SLCCG3AHD Mark V LAN Communication Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200SLCCG3AHD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200SLCCG3AHD\u003c\/strong\u003e LAN Communications Card (SLCC), operates as a dedicated hardware component for data exchange between the host controller and external networks within Mark V Speedtronic Turbine Control platforms. Configured for routing network packets and executing physical node interfacing, the \u003cstrong\u003eGE DS200SLCCG3AHD\u003c\/strong\u003e provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200SLCCG3AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg (Shipping weight: 3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e178 x 101 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC logic supply requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eEthernet \/ LAN compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connectors\u003c\/td\u003e\n\u003ctd\u003eEdge connectors and dedicated communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eDiagnostic LED array for link and power verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Profile\u003c\/td\u003e\n\u003ctd\u003eIntegrated optical and electrical noise isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating for environmental resilience\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Level\u003c\/td\u003e\n\u003ctd\u003eG3AHD (backward compatible with baseline G3 boards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Architecture\u003c\/h3\u003e\n\u003cp\u003eThe card architecture incorporates specialized transceiver arrays designed to maintain stable backplane bus communication velocity Licences and enforce strict firmware flash compatibility across the legacy rack assembly. The onboard multi-layer printed circuit board employs optical and electrical isolation barriers to shield internal processing logic from common-mode noise and ground potential fluctuations inherent in distributed topologies. Onboard configuration jumpers manage hardware address mapping and signal path optimization, while a dedicated array of diagnostic LEDs displays physical line activity and link state telemetry directly on the faceplate.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the G3AHD hardware revision designation impact installation in an older Mark V panel?\u003c\/p\u003e\n\u003cp\u003eA: The G3AHD revision denotes incremental circuit optimizations that maintain backward compatibility with preceding G3 baseline versions, requiring no modifications to the backplane architecture or system software parameters.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the turbine control system is online?\u003c\/p\u003e\n\u003cp\u003eA: No, live extraction or insertion of the card is prohibited. Power down the sub-rack logic supply before card removal to prevent transient data bus corruption or destructive electrical arcs across the edge connectors.\u003c\/p\u003e\n\u003cp\u003eQ: What method is used to protect the communication paths from electromagnetic interference within the cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The hardware utilizes localized optical couplers and galvanic isolation barriers to break ground loops and intercept electrical noise before it enters the internal bus processing logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all incoming 5 VDC logic power lines and terminal connections are fully de-energized prior to beginning hardware extraction.\u003c\/li\u003e\n\u003cli\u003eGround yourself using a static-dissipative wrist strap connected to a verified earth point on the cabinet frame before removing the card from its packing enclosure.\u003c\/li\u003e\n\u003cli\u003eMatch the physical jumper positions on the new G3AHD assembly exactly to the configuration established on the card targeted for replacement.\u003c\/li\u003e\n\u003cli\u003eInsert the multi-layer edge connectors straight into the card-cage chassis guides, pushing firmly on the corners until the structural tabs seat into the backplane receptacle.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44389335203939,"sku":"DS200SLCCG3AHD","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/431._1d0eb391-6465-4d43-ac61-80c10e9d4d68.jpg?v=1784712946","url":"https:\/\/www.autocontrolglobal.com\/products\/mark-v-lan-communications-card-ge-ds200slccg3ahd","provider":"AutoControl Global","version":"1.0","type":"link"}