{"product_id":"micro-discrete-input-expansion-module-ge-fanuc-ic200uei016","title":"Micro discrete input expansion module GE Fanuc IC200UEI016","description":"\u003ch2\u003eGE Fanuc IC200UEI016 VersaMax Micro Expansion Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UEI016\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UEI016\u003c\/strong\u003e Input Expansion Module, operates as a dedicated hardware component for discrete signal acquisition within VersaMax Micro platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEI016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.0 cm x 8.0 cm x 2.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC standard supply via expansion link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16 discrete points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Nom\u003c\/td\u003e\n\u003ctd\u003e7.5 mA per point at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Display\u003c\/td\u003e\n\u003ctd\u003eLED indicators per input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Deterministic Networks Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC200UEI016 leverages a precise I\/O density scaling footprint to minimize parallel mounting rail footprints while doubling the physical input processing threshold of the host assembly. Interfacing through the proprietary expansion bus, the module routes serialized discrete channel registers to the host processor using deterministic network clock sequences. The integration protocol employs a localized firmware flash compatibility interface, guaranteeing cyclic data parity during high-frequency signal state transitions. This configuration enforces hardware filtering options across all 16 channels, neutralizing contact bounce and suppressing electrical signal noise before the logic reaches the central controller backplane bus communication velocity rails.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical constraints regarding hot-swapping the IC200UEI016 module during active runtime operations?\u003c\/p\u003e\n\u003cp\u003eA: The VersaMax Micro expansion bus does not support hot-swap capabilities. Complete isolation of the primary 24 VDC logic power supply is required prior to uncoupling the expansion cable to avoid logical bus failure or permanent damage to the solid-state diagnostic circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal isolation boundary function when adjacent input loops experience localized transient voltage spikes?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on integral channel-to-channel galvanic isolation paths. This layout blocks high-voltage differential transients up to the maximum physical layer parameters, restricting fault propagation to the affected circuit loop and preserving backplane processing continuity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eBus Interface Interconnection: Ensure the expansion base unit is entirely de-energized before coupling the provided expansion connection cable to the interface socket.\u003c\/p\u003e\n\u003cp\u003eDIN-Rail Mounting Stability: Snap the module housing firmly onto standard 35 mm DIN-rail. Verify that the rear ground spring clip seats directly against an unpainted section of the metallic rail to confirm a continuous low-impedance chassis ground path.\u003c\/p\u003e\n\u003cp\u003eField Conductor Management: Separate 24 VDC discrete routing conductors from heavy AC power wiring grids or variable-frequency drive leads within the enclosure wire ducts to eliminate electromagnetic noise coupling into the 7.5 mA input loops.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872736706659,"sku":"IC200UEI016","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/401.1_57a563d5-02ec-427b-9cf9-f8bf9fc1cf58.jpg?v=1764914476","url":"https:\/\/www.autocontrolglobal.com\/products\/micro-discrete-input-expansion-module-ge-fanuc-ic200uei016","provider":"AutoControl Global","version":"1.0","type":"link"}