{"product_id":"mo325-9-0-abb-9-a-magnetic-only-manual-motor-starter","title":"MO325-9.0 ABB 9 A Magnetic Only Manual Motor Starter","description":"\u003ch2\u003eABB MO325-9.0 Manual Motor Starter\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB MO325-9.0\u003c\/strong\u003e (1SAM160000R1010) is a 3-pole manual motor starter designed for magnetic-only short-circuit protection and manual switching of motor loads up to 9 A. Equipped with an instantaneous short-circuit setting of 135 A and an integrated rotary operating handle, it delivers fuseless protection and clear disconnect status within a compact 54 mm housing.\u003c\/p\u003e\n\u003ch3\u003eShort-Circuit Protection and Switching Performance\u003c\/h3\u003e\n\u003cp\u003eFeaturing an electromagnetic tripping mechanism, the starter provides quick fault interruption with a rated service short-circuit breaking capacity (Ics) of 100 kA at 400 V AC. The trip-free mechanism ensures circuit interruption during fault conditions even if the handle is held in the ON position.\u003c\/p\u003e\n\u003ch3\u003eSystem Configuration and Protection Requirements\u003c\/h3\u003e\n\u003cp\u003eThe device integrates a disconnect function and supports operational voltages up to 690 V AC across 50\/60 Hz single-phase and three-phase systems. Because the unit provides magnetic protection only, full motor protection requires pairing with an external thermal or electronic overload relay.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMO325-9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Product Type\u003c\/td\u003e\n\u003ctd\u003eMO325-9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e1SAM160000R1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4013614302060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManual Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic Short-Circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie)\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003eUp to 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous Short-Circuit Setting\u003c\/td\u003e\n\u003ctd\u003e135 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mechanism\u003c\/td\u003e\n\u003ctd\u003eRotary Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Function\u003c\/td\u003e\n\u003ctd\u003eManual ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eNot integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisconnect Function\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Mechanism\u003c\/td\u003e\n\u003ctd\u003eTrip-free mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e87.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Depth\u003c\/td\u003e\n\u003ctd\u003e75.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MO325-9.0 provide thermal overload protection? A: No, the MO325-9.0 provides magnetic short-circuit protection only. Complete motor overload protection requires an additional thermal or electronic overload relay.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting option does this manual motor starter use? A: The starter is designed to mount on a standard 35 mm DIN rail.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43777304428643,"sku":"MO325-9.0 1SAM160000R1010","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/935..jpg?v=1793343212","url":"https:\/\/www.autocontrolglobal.com\/products\/mo325-9-0-abb-9-a-magnetic-only-manual-motor-starter","provider":"AutoControl Global","version":"1.0","type":"link"}