Modicon Modbus Cable Schneider 170MCI10001
Manufacturer: Schneider
-
Part Number: 170MCI10001
Condition:New with Original Package
Product Type: Communication Cables
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Schneider Electric 170MCI10001 Modicon Momentum Modbus RTU Interface Cable
Configured for Modbus RTU serial communication in Modicon Momentum platforms, the Schneider Electric 170MCI10001 (170MCI10001 Communication Cable) provides direct physical/electrical execution. It establishes RS-485 serial data paths between Momentum processors and distributed field devices, transmitting commands across shielded twisted-pair media.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 170MCI10001 |
| Brand | Schneider Electric |
| Origin | Consult Factory |
| Weight | Consult Factory |
| Dimensions | 141.5 x 125 x 47.5 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | Powered via connected I/O base |
| Cable Length | 1 m |
| Protocol | Modbus RTU (Master/Slave) |
| Physical Layer | RS-485, 2-wire shielded twisted pair |
| Transmission Rate | 300 bit/s to 19.2 kbit/s |
| Connectors | DB9 connector |
Backplane Bus Communication and Firmware Flash Compatibility
The serial cable assembly interfaces directly with the Modicon Momentum port, transferring Modbus RTU frames across RS-485 networks at speeds up to 19.2 kbit/s. Automation engineers maintain strict firmware flash compatibility across attached controllers to preserve frame timing and baud rate synchronization. Furthermore, high backplane bus communication velocity and integrated bus-to-logic isolation prevent electrical noise from disrupting multi-drop network nodes.
Frequently Asked Questions
Q: Can the 170MCI10001 cable be connected or disconnected while system power is active?
A: Live plugging or extraction of serial communication connectors is not recommended while bus voltage is applied, as transient arcs can corrupt active packet transmissions or damage interface ports. Disconnect power before servicing.
Q: How many physical nodes does a single RS-485 segment support using this cable?
A: The physical layer specification supports a multi-drop bus topology accommodating up to 32 nodes per segment without additional line repeaters.
Field Installation Guidelines
Inspect the DB9 connectors for pin integrity before attaching the assembly to the Modicon Momentum base port. Tighten the integral securing screws firmly to ensure continuous grounding through the cable shield. Route the 1-meter cable away from high-voltage AC lines and variable frequency drives to prevent electromagnetic interference from degrading serial data signals.