MTL4575 Honeywell ATEX Rated Hazardous Area Converter
Manufacturer: Honeywell
-
Part Number: MTL4575
Condition:New with Original Package
Product Type: Temperature Converters
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell MTL4575 (MTL 4575) represents the industry standard for high-performance signal conditioning in hazardous process environments. This 100% brand new, original temperature converter serves as a robust interface between field-mounted sensors and safe-area control equipment. It accepts low-level DC millivolt signals from virtually all thermocouple types or resistance temperature detectors (RTDs) and transforms them into a linearized, industry-standard 4–20 mA current loop. As a cornerstone of the MTL4500 Series, the MTL4575 provides essential galvanic isolation, ensuring that high-voltage transients in the safe area never compromise the integrity of intrinsically safe (IS) field circuits.
Technical Specifications
The MTL4575 utilizes sophisticated 3-port isolation (input, output, and power) to eliminate ground loops and minimize signal noise in Distributed Control Systems (DCS).
| Specification | Technical Detail |
| Product Function | THC or RTD to 4–20 mA Converter |
| Input Compatibility | THC (Types J, K, T, E, R, S, B, N) or RTD (Pt100) |
| Output Signal | 4–20 mA (Sink or Source) |
| Isolation | 3-port galvanic isolation (250V AC/DC) |
| Power Supply | 20 to 35 V DC via Power Rail |
| Linearization | Software-selectable |
| Mounting Type | DIN rail (via Power Rail) |
| Operating Temp | –20°C to +60°C |
| Dimensions | 17.5 mm (W) × 110 mm (H) × 120 mm (D) |
| Safety Approvals | ATEX, IECEx, FM, CSA |
| Typical Load | 0 to 600 Ω |
Engineering Advantages
The Honeywell MTL4575 addresses complex instrumentation challenges through superior electrical engineering and physical design:
-
Elimination of Signal Interference: The 3-port isolation architecture prevents cross-talk between the power supply and the signal loop. This ensures that the DCS or Emergency Shutdown System (ESD) receives a clean, accurate temperature reading even in environments with high electromagnetic interference (EMI).
-
Universal Input Versatility: A single MTL4575 module replaces multiple dedicated units. Engineers configure the input type—whether a Type K thermocouple or a Pt100 RTD—via software, significantly reducing spare part inventory requirements across the facility.
-
High-Density Cabinet Utilization: The ultra-slim 17.5 mm width maximizes rail space. This compact footprint allows for more measurement points within a standard marshalling cabinet, reducing the total number of enclosures required for large-scale F&G (Fire & Gas) monitoring systems.
-
Rapid Power Integration: The module draws power directly from the MTL Power Rail. This "plug-and-play" power connection eliminates the need for individual wiring to each unit, which speeds up commissioning and simplifies future maintenance or hot-swapping procedures.
FAQs
-
Does the MTL4575 require manual calibration for different thermocouple types?
No. The MTL4575 utilizes software-selectable configuration. You define the sensor type, range, and tagging through the MTL configuration interface, which automatically applies the correct linearization curves for the selected sensor.
-
Can the MTL4575 detect a sensor failure?
Yes. The module includes sophisticated sensor break detection. You can configure the output to go "Upscale" or "Downscale" upon detecting an open-circuit thermocouple or a faulty RTD, providing immediate notification to the control system.
-
Is this module compatible with legacy MTL4000 series systems?
The MTL4575 is a modern 4500 series module. While it shares many functional traits with previous series, it specifically utilizes the MTL Power Rail system and standard DIN rail mounting. Always verify backplane compatibility if upgrading an existing installation.
-
What is the benefit of "Intrinsically Safe" certification for this device?
The IS certification ensures that the MTL4575 limits the energy sent to the hazardous area to levels that cannot ignite explosive atmospheres (gases or dust), allowing the use of standard temperature probes without expensive explosion-proof enclosures.