{"product_id":"new-honeywell-8c-paoha-analog-output-module-experion-pks","title":"New Honeywell 8C-PAOHA Analog Output Module Experion PKS","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAOHA (Part Number: 51454469-275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision 16-channel analog output interface for the Experion PKS Series 8 I\/O platform. It generates accurate 4–20 mA signals to drive critical final control elements, including control valve positioners, dampers, and I\/P converters. Each channel features an integrated HART modem, allowing the C300 controller to perform remote calibration and retrieve advanced device diagnostics. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging to ensure peak performance in mission-critical process automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 8C-PAOHA incorporates high-resolution D\/A conversion and robust electrical protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Independent Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA (Standard); 0–20 mA (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated HART modem per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit D\/A conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.075% FS at 23.5 °C; ±0.15% FS (Full Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 750 Ω (with 24 VDC supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel and Channel-to-System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, ATEX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Control Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution provides granular signal control, which minimizes process dead-band and improves the positioning accuracy of control valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated HART modem on every channel eliminates the need for external multiplexers. This allows for simultaneous analog control and digital device configuration, enabling predictive maintenance through actuator travel signatures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Uptime:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports hot-swapping into the Series 8 chassis. Maintenance teams can replace a module under live power without disrupting neighboring signals or requiring a system reboot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Fail-Safe States:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a controller communication loss, the 8C-PAOHA sheds to user-defined \"Safe-state\" (FAILOPT) current levels. This prevents unmanaged valve movements and protects plant assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Electrical Ruggedness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for unconditioned field environments, the module operates reliably from -40 °C to +70 °C. Internal circuitry includes protection against over-voltage, over-current, and short-circuits to shield the I\/O backplane from field-side electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy packing 16 precision outputs into a standard Series 8 form factor, this module significantly reduces the required cabinet space compared to traditional lower-density hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does the 8C-PAOHA support 0-20 mA signals for older actuators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While 4-20 mA is the industrial standard, you can configure the module through the Experion Configuration Studio to provide a 0-20 mA output range if your specific field equipment requires it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the benefit of the \"Precision\" designation compared to standard AO modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Precision\" version (8C-PAOHA) offers tighter accuracy specs (±0.075% FS typical) and better thermal stability. This makes it the preferred choice for high-stakes control loops, such as feed-water control or pressure regulation in power and chemical sectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can I replace a failed module without rewiring the IOTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The module plugs directly into the Input Output Termination Assembly (IOTA). All field wiring remains permanently attached to the IOTA terminals, allowing you to swap the electronic module in seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How does the module handle a short-circuited field wire?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAOHA includes active short-circuit protection. If it detects a fault in the field wiring, the module limits the output current and triggers a real-time diagnostic alarm in the Experion PKS operator station.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44142850310243,"sku":"8C-PAOHA","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/366.1_95e7fa3a-0095-4aaa-ab87-ce7e19a34508.jpg?v=1777255413","url":"https:\/\/www.autocontrolglobal.com\/products\/new-honeywell-8c-paoha-analog-output-module-experion-pks","provider":"AutoControl Global","version":"1.0","type":"link"}