{"product_id":"ocr1100-emerson-ovation-datasheet-technical-manual","title":"OCR1100 Emerson Ovation Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eEmerson OCR1100 Ovation Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson OCR1100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eOCR1100\u003c\/strong\u003e Controller, serves as the primary \u003cstrong\u003eOCR1100\u003c\/strong\u003e Controller utilized to execute serial and parallel I\/O scanning across Ovation Distributed Control System platforms. The module executes deterministic algorithmic logic loops on an integrated Intel Atom Z510 processor core, coordinating real-time process data acquisition and state changes over local and virtual network boundaries.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOCR1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eField industrial standard rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact footprint housing design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eField industrial standard rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow power fanless design consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom Z510, 1100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e256 MB DRAM (expandable to 1 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e128 MB Compact Flash (expandable to 2 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 4,778 direct-wired I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8,192 virtual I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Capability\u003c\/td\u003e\n\u003ctd\u003eUp to 1,024 Sequence of Events points per controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-3, Achilles Level 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe OCR1100 manages up to 5 distinct control areas with software-selectable scan rates adjustable from 10 ms to 30,000 ms. Built with an architecture supporting automatic, non-interruptive failover between redundant controller pairs, it ensures constant process state execution in the event of primary module degradation. The onboard memory sub-tier uses 256 MB DRAM and 128 MB Compact Flash with SiSmart technology storage management. For tracking high-speed plant trips, the hardware logs up to 1,024 Sequence of Events (SOE) points natively with an internal event resolution of 1 ms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the OCR1100 manage network security parameters for external data loops?\u003c\/p\u003e\n\u003cp\u003eA: The controller features Achilles Level 1 certification, verifying that its integrated Ethernet communication stack has undergone cyber-security vulnerability testing against denial-of-service (DoS) vectors and boundary exploitation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the exact physical and virtual tag configuration boundaries per module?\u003c\/p\u003e\n\u003cp\u003eA: A single hardware node handles a maximum threshold of 4,778 direct physical-wired I\/O points alongside a maximum of 8,192 virtual I\/O channels allocated for Ethernet-based third-party system integration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Pair Placement\u003c\/strong\u003e: Install the primary and secondary OCR1100 controllers in adjacent, dedicated slots on the Ovation backplane carrier. Connect the synchronization link cables completely to enable real-time mirror imaging of the runtime registries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Flash Handling\u003c\/strong\u003e: Only unseat or replace the internal Compact Flash storage media when the module power rail is completely isolated, or when standard engineering software tools have safely dismounted the storage subsystem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Ventilation Spacing\u003c\/strong\u003e: Though the fanless processor design minimizes active heat dissipation, maintain standard clear perimeter spacing inside the enclosure to allow natural convection currents to cool the outer metal fins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43829344665699,"sku":"OCR1100","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/65_dc3e7b09-63ab-4a8d-b2f8-e5fca605f17e.jpg?v=1762762965","url":"https:\/\/www.autocontrolglobal.com\/products\/ocr1100-emerson-ovation-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}