Foxboro P0926ZM P-Series Pressure Measurement Transmitter
Manufacturer: Foxboro
-
Part Number: P0926ZM
Condition:New with Original Package
Product Type: Pressure Transmitters
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Foxboro P0926ZM P-Series Pressure Measurement Transmitter
The Foxboro P0926ZM, also cataloged as the P0926ZM Pressure Transmitter, operates as a dedicated hardware component for continuous pressure sensing and signal conditioning within Foxboro I/A Series and Evo DCS networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | P0926ZM |
| Brand | Foxboro |
| Origin | United States |
| Weight | 0.24 kg |
| Dimensions | Standard P-Series Enclosure Dimensions |
| Operating Temp | -40 to +85 deg C |
| Storage Temp | -40 to +85 deg C |
| Power Consumption | Standard Loop Powered (24 V DC nominal) |
| Measurement Range | 0.25 psi up to 10,000 psi |
| Accuracy | +/-0.15% of full scale |
| Output Signal | 4-20 mA DC |
4-20 mA HART Loop Protocol & Channel Isolation
The transmitter utilizes a 4-20 mA DC current loop topology to transmit process variable measurements directly to control system analog input cards. Integrated channel-to-channel isolation components safeguard internal piezoresistive sensor electronics against common-mode voltage spikes and electrical ground potential differences. Internal filtering circuitry attenuates ambient electromagnetic interference (EMI) across the two-wire interface, ensuring stable signal integrity across long-distance field wiring runs without signal degradation.
Frequently Asked Questions
Q: What power supply voltage range does the P0926ZM require for loop operation?
A: The transmitter operates on a nominal 24 V DC loop supply, functioning within standard two-wire transmitter power limits to maintain proper current loop excitation under varied load resistance.
Q: How does internal channel isolation protect the P0926ZM in high-noise industrial environments?
A: Galvanic isolation barriers physically separate the sensing diaphragm electronics from the field wiring terminals, suppressing stray ground loops and preventing transient surges from damaging the internal processing unit.
Q: What cable shield termination technique is recommended for the 4-20 mA output loop?
A: Cable shield drain wires must be connected to a dedicated instrument earth ground terminal at the control cabinet side only, leaving the field sensor shield ungrounded to avoid noise-inducing ground loops.
Field Installation Guidelines
- Mount the transmitter securely onto the process piping or mounting bracket, ensuring proper engagement of all NPT threaded mechanical connections.
- Verify process fluid compatibility and apply appropriate thread sealant prior to final mechanical torqueing.
- Route two-wire twisted shielded pair conductors through dedicated conduit openings to prevent moisture ingress into the terminal compartment.
- Terminate positive and negative power loop leads at the marked internal terminal screws, ensuring correct polarity before applying 24 V DC power.
- Connect the wiring shield drain wire exclusively to the central instrument grounding bar at the cabinet end.