{"product_id":"pacsystems-rx3i-discrete-dc-input-ic694mdl634-ge","title":"PACSystems RX3i Discrete DC Input | IC694MDL634 GE","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL634\u003c\/strong\u003e serves as a specialized discrete input interface for the \u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e automation platform. This \u003cstrong\u003e100% Brand New\u003c\/strong\u003e original module provides 8 isolated input points, allowing the PLC to acquire digital signals from field devices such as limit switches, proximity sensors, and pushbuttons. By supporting both positive and negative logic (sink\/source) on a single module, the \u003cstrong\u003eIC694MDL634\u003c\/strong\u003e ensures maximum compatibility with diverse field wiring standards. It provides a robust, electrically isolated bridge between high-voltage field environments and sensitive PLC logic circuitry.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC694MDL634\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete DC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Points (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePositive or Negative Logic (Sink\/Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRX3i Universal Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V between field side and logic side\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 mA per point @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual LED status indicators for each point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard RX3i Single-slot Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Logic Compatibility:\u003c\/strong\u003e The \u003cstrong\u003eIC694MDL634\u003c\/strong\u003e accepts both positive and negative logic inputs. This capability allows engineers to standardize on a single module type regardless of whether the field sensors utilize NPN or PNP configurations, significantly reducing spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Electrical Protection:\u003c\/strong\u003e The module features 1500V galvanic isolation between the field-side wiring and the RX3i backplane. This protects the CPU and other sensitive control modules from ground loops, high-voltage surges, and electrical noise common in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Diagnostics:\u003c\/strong\u003e Eight dedicated green LED indicators on the front faceplate provide immediate visual confirmation of input status. Maintenance teams can verify field-side signal activity at a glance, bypassing the need for software diagnostic tools during initial troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Design:\u003c\/strong\u003e GE Fanuc engineers this module for continuous operation in unconditioned cabinets. It maintains high signal integrity even when subjected to the vibrations and thermal fluctuations typical of oil \u0026amp; gas or power generation facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Power Signature:\u003c\/strong\u003e Drawing minimal current from the backplane, the \u003cstrong\u003eIC694MDL634\u003c\/strong\u003e minimizes heat dissipation within the RX3i rack. This thermal efficiency contributes to a longer service life for all components within the control enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC694MDL634 replace a 16-point or 32-point input module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it operates on the same voltage and logic principles, the \u003cstrong\u003eIC694MDL634\u003c\/strong\u003e provides only 8 points. If you are replacing a high-density module, ensure your existing application logic and wiring footprint can accommodate the lower point count or utilize multiple 8-point modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \u003cstrong\u003eIC694MDL634\u003c\/strong\u003e utilizes the standard RX3i removable terminal block (RTB). This allows for \"pre-wiring\" of the cabinet and permits module replacement without disconnecting individual field wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with the older Series 90-30 system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While some IC693 modules work in RX3i racks, the IC694 series specifically targets the high-speed \u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e universal backplane to leverage advanced diagnostic and throughput capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44075613126755,"sku":"IC694MDL634","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/401_496bc69a-8891-4b33-a21a-a770c26db1f9.jpg?v=1774334954","url":"https:\/\/www.autocontrolglobal.com\/products\/pacsystems-rx3i-discrete-dc-input-ic694mdl634-ge","provider":"AutoControl Global","version":"1.0","type":"link"}