{"product_id":"pacsystems-rx3i-ic694mdl741-ge-fanuc-dc-output-module","title":"PACSystems RX3i IC694MDL741 GE Fanuc DC Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL741\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a PACSystems RX3i discrete DC output module designed for stable and predictable control of field devices such as relays, solenoids, indicator lamps, and DC actuators. Integrated into the RX3i PLC platform, this module provides 16 high-reliability output channels arranged in two electrically isolated groups, supporting demanding industrial control environments.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL741\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates on a 12–24 VDC output range with positive logic wiring and optical isolation between field wiring and the backplane. This design enhances noise immunity and protects the controller from transient field conditions. Output status LEDs allow fast visual diagnostics during commissioning and maintenance, while the module’s fast response time supports time-critical control tasks.\u003c\/p\u003e\n\u003cp\u003eDesigned for long-term use in PACSystems RX3i racks, the module draws power directly from the backplane and does not require an external supply, simplifying cabinet design and reducing wiring complexity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC694MDL741\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Groups\u003c\/td\u003e\n\u003ctd\u003e2 groups, 8 outputs per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 \/ 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e12–24 VDC (+20%, −15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Current\u003c\/td\u003e\n\u003ctd\u003e2 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.5 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-state Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn Response Time\u003c\/td\u003e\n\u003ctd\u003e≤ 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff Response Time\u003c\/td\u003e\n\u003ctd\u003e≤ 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eField-to-backplane and frame ground, 250 VAC continuous, 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e110 mA (all outputs ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE PACSystems RX3i PLC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43968137265251,"sku":"IC694MDL741","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/45._42d999e9-6120-428f-b100-1ed2d6b558d0.jpg?v=1769416064","url":"https:\/\/www.autocontrolglobal.com\/products\/pacsystems-rx3i-ic694mdl741-ge-fanuc-dc-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}