{"product_id":"pm573-eth-abb-ac500-plc-processor-module","title":"PM573-ETH ABB AC500 PLC Processor Module","description":"\u003ch2\u003eABB PM573-ETH AC500 Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB PM573-ETH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePM573\u003c\/strong\u003e Processor Module (Product ID \u003cstrong\u003e1SAP130300R0271\u003c\/strong\u003e), operates as a dedicated hardware component for high-speed logic execution and multi-protocol network communication within ABB AC500 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePM573-ETH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e67.5 mm x 76 mm x 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB AC500 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Memory\u003c\/td\u003e\n\u003ctd\u003e512 kB program and data memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e1x Ethernet, 2x RS232\/RS485, 1x FieldBus Plug (FBP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP, CANopen, PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eIntegrated LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe processor executes cyclic control logic while driving high-speed backplane bus communication velocity across attached AC500 I\/O expansion modules. Built-in network interfaces manage real-time packet exchange over EtherNet\/IP and Modbus TCP deterministic networks at 10\/100 Mbps transmission rates. Non-volatile onboard memory retention prevents data loss during unexpected power interrupts, while internal flash memory management ensures seamless firmware flash compatibility during online updates and system code revisions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CPU module require a separate battery to retain 512 kB user logic during power interruption?\u003c\/p\u003e\n\u003cp\u003eA: Internal non-volatile memory retains user program code and configuration parameter sets without external battery power, though real-time clock buffering utilizes an optional lithium battery.\u003c\/p\u003e\n\u003cp\u003eQ: Can communication expansion interfaces be attached without cycling main 24 VDC control power?\u003c\/p\u003e\n\u003cp\u003eA: No. System guidelines require completely removing 24 VDC input power before attaching or removing communication modules to prevent transient voltage spikes on the internal backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated LCD panel function during system runtime diagnostics?\u003c\/p\u003e\n\u003cp\u003eA: The LCD screen displays real-time CPU operational states, active error codes, IP address assignments, and system hardware status flags directly on the front panel faceplate.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the CPU module onto a standard 35 mm DIN rail inside an IP54-rated protective steel enclosure. Route 24 VDC power lines through stranded wire conductors, ensuring strict adherence to polarity markings on the terminal connector. Route Ethernet data cables and serial fieldbus wiring through dedicated wiring ducts isolated from AC power distribution conductors to eliminate electromagnetic interference. Fasten all communication cable shielding directly to a low-impedance ground rail located near the bottom of the enclosure.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43772252291171,"sku":"PM573","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/193_a5551d3c-cb9f-4b20-bf2e-4dc6a0e5d1d0.jpg?v=1760163908","url":"https:\/\/www.autocontrolglobal.com\/products\/pm573-eth-abb-ac500-plc-processor-module","provider":"AutoControl Global","version":"1.0","type":"link"}