{"product_id":"power-connect-card-assembly-ge-ds200pcca62acb","title":"Power Connect Card Assembly | GE DS200PCCA62ACB","description":"\u003ch2\u003eGE DS200PCCA62ACB Mark V Power Connect Card Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for power regulation and data routing in turbine control platforms, the \u003cstrong\u003eGE DS200PCCA62ACB\u003c\/strong\u003e (\u003cstrong\u003eDS200PCCA\u003c\/strong\u003e Power Connect Card Assembly) provides direct physical\/electrical execution. The board accepts a raw DC input, converting and stabilizing voltages to deliver regulated logic power while maintaining signal interfaces between the central turbine processor and auxiliary I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PCCA62ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e178 x 101 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC input \/ regulates 5 VDC logic supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003ePower Connect Card Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eMultiple edge connectors for I\/O interfacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptocoupler isolation for signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Indicators\u003c\/td\u003e\n\u003ctd\u003eLED diagnostics for power and signal status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Elements\u003c\/td\u003e\n\u003ctd\u003eConfiguration jumpers for system setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating over multi-layer PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Level\u003c\/td\u003e\n\u003ctd\u003e62ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Architecture\u003c\/h3\u003e\n\u003cp\u003eThe card design incorporates multi-layer PCB routing paired with optocoupler signal isolation to mitigate high-frequency electrical noise and prevent transient propagation across the control architecture. The module processes a 24 VDC external bus input to supply a regulated 5 VDC source to interconnected backplane components. Multiple edge connectors link discrete data paths directly to the processor, while firmware flash compatibility and hardwired configuration jumpers allow matching specific turbine control profiles without modification to the host logic framework.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the assembly indicate localized power or communication failures?\u003c\/p\u003e\n\u003cp\u003eA: The card features an onboard LED diagnostic array that delivers real-time visual validation of input power stability, regulated voltage output, and active bus signal states.\u003c\/p\u003e\n\u003cp\u003eQ: Can this power connect card be swapped out while the turbine panel is online?\u003c\/p\u003e\n\u003cp\u003eA: No, this card does not support hot-swapping. Complete system de-energization and formal lock-out\/tag-out (LOTO) protocols must be enforced prior to physical extraction.\u003c\/p\u003e\n\u003cp\u003eQ: What functions do the onboard jumpers perform during installation?\u003c\/p\u003e\n\u003cp\u003eA: The manual configuration jumpers modify physical circuit tracking and ground-fault loop parameters, enabling hardware alignment with specific turbine sensor and rack setups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all external 24 VDC lines and backplane supply feeds before unlocking the module chassis.\u003c\/li\u003e\n\u003cli\u003eWear a verified, grounded electrostatic discharge (ESD) wrist strap throughout the entire handling sequence to preserve the conformal coating and micro-components.\u003c\/li\u003e\n\u003cli\u003eAlign the board edge connectors precisely with the mating backplane slots before applying insertion force to prevent mechanical pin deflection.\u003c\/li\u003e\n\u003cli\u003eEnsure all structural chassis mounting screws are tightened to establish a solid physical ground plane between the multi-layer PCB and the cabinet enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44389142790243,"sku":"DS200PCCA62ACB","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/92_13630ccb-05ee-4746-a6ee-6a4ddf9f75c8.jpg?v=1784709235","url":"https:\/\/www.autocontrolglobal.com\/products\/power-connect-card-assembly-ge-ds200pcca62acb","provider":"AutoControl Global","version":"1.0","type":"link"}