Power Supply Module | GE VersaMax IC200PWR101F
Manufacturer: GE Fanuc
-
Part Number: IC200PWR101F
Condition:New with Original Package
Product Type: Power Supplies
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC200PWR101 VersaMax Power Supply Module
The GE Fanuc IC200PWR101F, also cataloged as the IC200PWR101 Power Supply Module, operates as a dedicated hardware component for power conditioning and regulated voltage distribution within GE Fanuc VersaMax I/O systems. The unit converts an incoming 120/240 VAC line source into stable 5 VDC and 3.3 VDC backplane outputs, supplying up to 1.5 A maximum output current to drive backplane bus communications and attached I/O modules. Integrated 1500 V RMS isolation prevents external AC line disturbances from penetrating sensitive processing logic during industrial switching events.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC200PWR101F |
| Brand | GE Fanuc / Emerson |
| Origin | USA / Assembled globally |
| Weight | 0.28 kg (0.63 lbs) |
| Dimensions | 120 mm x 90 mm x 50 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 27 VA input power requirement |
| Input Voltage Range | 120/240 VAC (85-264 VAC, 47-63 Hz) |
| Backplane Output Voltage | 5 VDC and 3.3 VDC |
| Maximum Output Current | 1.5 A max (0.25 A max at 3.3 VDC) |
| Holdup Time | 20 ms |
| Isolation Voltage | 1500 V RMS input-to-output |
| Protection | Short circuit, overload, overvoltage |
Firmware Flash Compatibility & Backplane Bus Communication Velocity
The IC200PWR101F attaches directly to the head of the VersaMax carrier rack, maintaining consistent 5 VDC backplane power rails without introducing voltage ripple or signal latencies across adjacent I/O modules. Firmware flash compatibility across legacy GE Fanuc CPUs and contemporary Emerson automation nodes remains fully supported, allowing seamless drop-in operation. The internal regulation circuit maintains bus communication velocity during momentary supply disruptions by utilizing a 20 ms holdup time to sustain processing registers.
Frequently Asked Questions
Q: What is the primary function of the 20 ms holdup time in the IC200PWR101F power supply?
A: The 20 ms holdup time preserves internal 5 VDC backplane power during brief AC input voltage sags, preventing unexpected CPU resets and maintaining active bus communications.
Q: Can the IC200PWR101F module be hot-swapped while the main AC line power is active?
A: No, field technicians must disconnect input AC power to the removable terminal block prior to removing or seating the module on the carrier base to prevent electrical arcing across backplane pins.
Q: How does the module handle output short-circuit conditions on the backplane bus?
A: The module contains internal current-limiting protection circuits that trip during overload or short-circuit events, clamping the output until the fault on the backplane is removed.
Field Installation Guidelines
Mount the VersaMax carrier base securely onto a standard 35 mm DIN rail or directly to a metallic enclosure backplate using screw fasteners. Slide the IC200PWR101F power supply into the designated leftmost slot of the carrier until the mechanical locking tabs latch firmly into place. Connect 120/240 VAC input conductors to the removable terminal block, ensuring tight screw torque on all terminal points. Route incoming AC line power separate from low-voltage DC data lines to avoid electromagnetic interference. Connect a low-impedance copper wire from the protective earth terminal directly to the central enclosure ground bus.