{"product_id":"power-supply-module-ge-versamax-ic200pwr101f","title":"Power Supply Module | GE VersaMax IC200PWR101F","description":"\u003ch2\u003eGE Fanuc IC200PWR101 VersaMax Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200PWR101F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200PWR101\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power conditioning and regulated voltage distribution within GE Fanuc VersaMax I\/O systems. The unit converts an incoming 120\/240 VAC line source into stable 5 VDC and 3.3 VDC backplane outputs, supplying up to 1.5 A maximum output current to drive backplane bus communications and attached I\/O modules. Integrated 1500 V RMS isolation prevents external AC line disturbances from penetrating sensitive processing logic during industrial switching events.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR101F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Assembled globally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 90 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27 VA input power requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC (85-264 VAC, 47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC and 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e1.5 A max (0.25 A max at 3.3 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS input-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort circuit, overload, overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Backplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe IC200PWR101F attaches directly to the head of the VersaMax carrier rack, maintaining consistent 5 VDC backplane power rails without introducing voltage ripple or signal latencies across adjacent I\/O modules. Firmware flash compatibility across legacy GE Fanuc CPUs and contemporary Emerson automation nodes remains fully supported, allowing seamless drop-in operation. The internal regulation circuit maintains bus communication velocity during momentary supply disruptions by utilizing a 20 ms holdup time to sustain processing registers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the 20 ms holdup time in the IC200PWR101F power supply?\u003c\/p\u003e\n\u003cp\u003eA: The 20 ms holdup time preserves internal 5 VDC backplane power during brief AC input voltage sags, preventing unexpected CPU resets and maintaining active bus communications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200PWR101F module be hot-swapped while the main AC line power is active?\u003c\/p\u003e\n\u003cp\u003eA: No, field technicians must disconnect input AC power to the removable terminal block prior to removing or seating the module on the carrier base to prevent electrical arcing across backplane pins.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output short-circuit conditions on the backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The module contains internal current-limiting protection circuits that trip during overload or short-circuit events, clamping the output until the fault on the backplane is removed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the VersaMax carrier base securely onto a standard 35 mm DIN rail or directly to a metallic enclosure backplate using screw fasteners. Slide the IC200PWR101F power supply into the designated leftmost slot of the carrier until the mechanical locking tabs latch firmly into place. Connect 120\/240 VAC input conductors to the removable terminal block, ensuring tight screw torque on all terminal points. Route incoming AC line power separate from low-voltage DC data lines to avoid electromagnetic interference. Connect a low-impedance copper wire from the protective earth terminal directly to the central enclosure ground bus.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44621579485283,"sku":"IC200PWR101F","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/289._56cd0fec-c6d9-445a-bcec-da74936dbf44.jpg?v=1789435532","url":"https:\/\/www.autocontrolglobal.com\/products\/power-supply-module-ge-versamax-ic200pwr101f","provider":"AutoControl Global","version":"1.0","type":"link"}