{"product_id":"power-supply-module-honeywell-900p01-0601-hc900","title":"Power Supply Module | Honeywell 900P01-0601 HC900","description":"\u003ch2\u003eHoneywell 900P01-0601 HC900 Series Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for specific technical tasks in ControlEdge HC900 systems, the \u003cstrong\u003eHoneywell 900P01-0601\u003c\/strong\u003e (\u003cstrong\u003eHoneywell 900P01\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. The hardware component conditions a universal AC input to deliver a regulated 24 VDC output rail, sustaining nominal operating power for central processing units, remote scanners, and high-density I\/O configurations under full electrical loads.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P01-0601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3-0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 100 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e130 VA (Input Rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e6 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eGreater than 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Circuits\u003c\/td\u003e\n\u003ctd\u003eOvervoltage (OVP), Overcurrent (OCP), Short-Circuit (SCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eGreen LED (Normal), Red LED (Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew-type, #12-22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5%-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL508, CSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Process Control Integrity\u003c\/h3\u003e\n\u003cp\u003eOperating within the Honeywell DCS architecture, this power supply module utilizes structural channel-to-channel isolation barriers to block high-frequency common-mode noise propagation. The isolation design ensures that voltage fluctuations on the primary AC line do not induce electrical interference across adjacent analog circuits or interrupt 4-20 mA HART loop protocol signaling. By establishing distinct galvanic decoupling between the input source and internal system logic, the unit prevents ground loops and maintains signal resolution across distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 900P01-0601 module support direct installation into international grid systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The unit accepts a universal input voltage range from 100 VAC to 240 VAC at 50\/60 Hz, allowing direct commissioning on standard global power grids without external step-down transformers.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module execute a fail-safe reaction during an overcurrent or short-circuit event?\u003c\/p\u003e\n\u003cp\u003eA: The module activates built-in overcurrent (OCP) and short-circuit protection (SCP) networks instantly. The system changes the front status indicator from Green (normal) to Red (fault) and cuts output delivery until the field fault is cleared.\u003c\/p\u003e\n\u003cp\u003eQ: Can this specific power supply drive remote I\/O scanner racks in standard configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 6 A, 144 W continuous power rating provides adequate capacity to drive standard HC900 controller racks, remote scanners, and associated local I\/O module combinations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Thermal Alignment:\u003c\/strong\u003e Fix the module securely to a standard DIN-rail or directly onto the enclosure backpanel. Maintain standard vertical orientation and leave adequate clearance gaps above and below the chassis to enable unobstructed natural convection airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Termination:\u003c\/strong\u003e Route input and output wiring separately to suppress cross-talk. Terminate all power lines using #12 AWG to #22 AWG wire, and torque the screw-type terminals to standard engineering specifications to ensure stable physical connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e Connect the primary protective earth wire directly to the designated ground terminal block on the chassis. Verify low-resistance path continuity to the central cabinet master ground bar to ensure effective surge dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Constraints:\u003c\/strong\u003e Verify that the internal cabinet ambient temperature stays within the -20 deg C to +60 deg C operating window, and take active measures to prevent moisture condensation on the terminal connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43868310012003,"sku":"900P01-0601","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/363_e5bf41f2-38a9-4d6f-baa3-8cb684428cdb.jpg?v=1764724870","url":"https:\/\/www.autocontrolglobal.com\/products\/power-supply-module-honeywell-900p01-0601-hc900","provider":"AutoControl Global","version":"1.0","type":"link"}