{"product_id":"profibus-dp-fieldbus-interface-module-honeywell-cc-pfb402","title":"Profibus-DP Fieldbus Interface Module | Honeywell CC-PFB402","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PFB402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-speed communication gateway between the Experion PKS C300 controller and distributed Profibus-DP field networks. This module integrates intelligent field instruments—such as motor starters, variable speed drives, and complex analytical transmitters—directly into the C300 control environment. By supporting the IEC 61158 standard, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic data exchange and comprehensive device diagnostics. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to guarantee peak system integrity and long-term operational stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB402\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: Profibus-DP (Master)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e: Selectable up to 12 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Slaves\u003c\/strong\u003e: Supports high-density Profibus device segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Rate\u003c\/strong\u003e: Configurable based on segment load and baud rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e: Supports 1:1 hardware redundancy for mission-critical loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Real-time communication monitoring and station status logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC Nominal (System Supplied)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 127 mm × 35 mm × 147 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Series C I\/O Termination Assembly (IOTA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Integration\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates data rates up to 12 Mbps, minimizing latency in high-speed motion control or motor management applications where timing is critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Device Management\u003c\/strong\u003e: Engineers utilize the Experion PKS configuration suite to map Profibus parameters directly into controller memory, removing the need for third-party protocol converters or complex gateway mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Data Link\u003c\/strong\u003e: The module incorporates advanced galvanic isolation and EMI shielding. These features prevent electrical noise from field-side cabling from migrating to the C300 processor backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Maintenance\u003c\/strong\u003e: Detailed diagnostic packets allow the system to identify specific device-level faults (e.g., wire breaks, configuration mismatches) without physical inspection of the field instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-PFB402 support Profibus-PA devices?\u003c\/strong\u003eThe module natively supports Profibus-DP. To connect Profibus-PA instruments, you must utilize a DP\/PA segment coupler or link device between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the PA network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a CC-PFB402 while the controller is running?\u003c\/strong\u003eIn a redundant configuration, the module supports hot-swapping. The secondary module maintains the communication link while you replace the faulty unit, ensuring zero process downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type is required for the CC-PFB402 connection?\u003c\/strong\u003eThe module requires standard Type A Profibus shielded twisted-pair cable (impedance 135–165 ohms) to achieve maximum baud rates and noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079990276195,"sku":"CC-PFB402","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/74_dceb79ec-4464-48f3-95a5-b22c6c4b0e09.jpg?v=1774493798","url":"https:\/\/www.autocontrolglobal.com\/products\/profibus-dp-fieldbus-interface-module-honeywell-cc-pfb402","provider":"AutoControl Global","version":"1.0","type":"link"}