{"product_id":"protective-excitation-module-ge-mark-vi-is200exhsg1aec","title":"Protective Excitation Module | GE Mark VI IS200EXHSG1AEC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200EXHSG1AEC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(EXHS) functions as a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh-Speed Relay Driver Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEX2100 Excitation Control System\u003c\/strong\u003e. This module serves as the critical hardware interface that translates digital trip and protection commands from the Mark VI controller into high-current relay actuation signals. By minimizing the interval between fault detection and mechanical relay switching, the IS200EXHSG1AEC ensures rapid generator de-excitation and emergency shutdowns. It provides the heavy-duty driving capacity required to manage protective relays in gas turbine, steam turbine, and large-scale industrial generator applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200EXHSG1AEC utilizes advanced surface-mount technology (SMT) to deliver high-density switching logic in a ruggedized format.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExciter High-Speed Relay Driver Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEX2100 Excitation Control \/ Mark VI Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Logic Execution and Relay Actuation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuitry Technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSurface-Mount Design (SMT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrip\/Protection commands from EX2100 Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed relay actuation signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to 149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33.0 cm (H) × 17.8 cm (W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Relay Actuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200EXHSG1AEC eliminates processing bottlenecks during emergency events. It processes protection commands and drives the associated relays with sub-millisecond switching speeds, ensuring the excitation system responds instantly to grid disturbances or internal faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Surface-Mount Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe use of surface-mount technology (SMT) enhances the board’s resistance to the high-frequency vibrations found in power generation halls. This vibration-hardened design prevents solder joint fatigue and ensures the protection logic remains operational over long service intervals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Endurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard driver cards, the EXHS board operates reliably in extreme temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30°C to +65°C\u003c\/strong\u003e. This resilience allows for installation in localized exciter cabinets where ambient heat or outdoor cold typically causes standard electronics to drift or fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Driving Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board features robust output transistors designed to handle the high inrush currents of industrial-grade trip relays. This eliminates the need for external interposing relays in many configurations, simplifying the overall cabinet wiring and reducing potential failure points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Protection Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200EXHSG1AEC incorporates hardwired fail-safe principles. If the board loses communication with the main controller, it utilizes onboard logic to maintain a safe state, preventing unauthorized excitation while ensuring the protection circuits stay primed for action.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the \"EC\" suffix in IS200EXHSG1AEC affect its application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"EC\" designation refers to the functional and artwork revision level. Specifically, \"EC\" models often include conformal coating or updated component specifications designed for enhanced moisture and contaminant resistance in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board replace a standard exciter feedback board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200EXHSG1AEC is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRelay Driver\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard. Its internal logic and circuitry are dedicated to outputting switching signals for protective relays. It does not contain the measurement circuitry found in feedback boards like the EACF.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the board require software configuration in ToolboxST?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the hardware itself is plug-and-play, the Mark VIe\/EX2100 system must recognize the board in the software configuration. You must verify that the hardware revision matches the configuration settings in ToolboxST to ensure correct diagnostic reporting and trip logic execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the IS200EXHSG1AEC suitable for hydro-generator excitation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Provided the hydro-generator utilizes the GE EX2100 control platform, this board provides the necessary high-speed relay driving capabilities required for hydro-protective logic and de-excitation sequences.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44092566896739,"sku":"IS200EXHSGREC","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/441._3db57e96-9bbc-46ae-8293-58f0101ae49f.jpg?v=1774946212","url":"https:\/\/www.autocontrolglobal.com\/products\/protective-excitation-module-ge-mark-vi-is200exhsg1aec","provider":"AutoControl Global","version":"1.0","type":"link"}