Proximity Probe & CON021 Converter Emerson EPRO PR6426/010-110
Proximity Probe & CON021 Converter Emerson EPRO PR6426/010-110
Proximity Probe & CON021 Converter Emerson EPRO PR6426/010-110
/ 3

Proximity Probe & CON021 Converter Emerson EPRO PR6426/010-110

  • Manufacturer: ABB

  • Part Number: CON021+PR6423/000-010

  • Condition:New with Original Package

  • Product Type: Proximity Sensors

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson EPRO PR6426/010-110 Proximity System

Configured for high-precision turbomachinery vibration and shaft position monitoring, the Emerson EPRO PR6426/010-110 (PR6423/000-010 Eddy-Current Proximity Sensor) provides direct electrical execution of rotor dynamics data acquisition.

Hardware Specifications

Parameter Specification
Model PR6426/010-110 (PR6423/000-010)
Brand Emerson EPRO
Origin Germany
Weight 0.9 kg
Dimensions 8 mm tip diameter / 10 m cable
Operating Temp -35 deg C to +180 deg C (Probe)
Power Consumption 24 VDC supply
Measurement Range 2 mm

Emerson TSI Characteristics

The PR6426/010-110 system utilizes high-resolution eddy-current probe scaling to convert non-contact shaft displacements into precise electrical outputs. The CON021 signal conditioner provides essential gap voltage validation, maintaining a -10 VDC baseline for accurate interpretation of rotor dynamics. System performance is optimized through effective cross-talk suppression, which ensures measurement clarity when multiple probes operate in close proximity.

The CON021 module facilitates I/O density scaling by offering standard 4-20 mA outputs for direct integration into PLC and DCS platforms. Additionally, galvanic isolation between the input and output stages safeguards the measurement chain against field-side electrical surges and ground loops.

Frequently Asked Questions

Q: Does the CON021 module provide access to raw signals for diagnostic analysis?

A: Yes, the CON021 module includes a buffered output terminal that provides the raw, unprocessed vibration signal. Technicians can connect portable analysis equipment to this terminal for transient data recording without disrupting the primary monitoring loop.

Q: How does the system signal a failure to the host controller?

A: The CON021 unit features a dedicated fault relay output that de-energizes upon detecting a sensor fault, such as an open circuit or signal clipping. Users must integrate this relay into a digital input module on the host PLC to trigger automatic machine protection sequences.

Field Installation Guidelines

  1. Gap Setting: Install the probe using a micrometer or feeler gauge to establish the nominal gap within the 0.25–2.25 mm linear range. Confirm the output gap voltage matches the -10 VDC baseline required for standard operation.
  2. Mounting: Thread the probe into the mounting bracket, ensuring it is positioned squarely relative to the shaft surface. Secure the assembly with the provided lock nuts to prevent vibration-induced movement during high-speed machine rotation.
  3. Cabling: Route the 10-meter integral cable through shielded, grounded conduit dedicated exclusively to low-voltage instrumentation. Maintain physical separation from high-current AC power cabling to minimize electromagnetic interference.
  4. Validation: After installation, verify the "Sensor OK" status on the CON021. A steady "OK" LED indicates the probe is detecting the target and the circuit loop is intact; a flashing or dark LED suggests a gap fault or signal clipping.
You may also like