{"product_id":"r9268-301-000-epro-electrodynamic-velocity-sensor","title":"R9268\/301-000 EPRO Electrodynamic Velocity Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EPRO R9268\/301-000 operates as a self-generating electrodynamic velocity sensor within the MMS 6000 machinery protection framework. This heavy-duty instrument measures absolute casing vibration by leveraging a seismic mass and coil moving through a permanent magnetic field. Plant engineers hard-mount the R9268\/301-000 horizontally onto the bearing housings of critical steam turbines, gas compressors, heavy industrial pumps, and high-load gearboxes to supply core tracking analytics for API 670 safety interlocks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe sensor features a robust industrial housing optimized for specific horizontal mechanical alignment on machine surfaces.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEPRO (Emerson \/ AMS Machinery Health)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR9268\/301-000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrodynamic (moving coil and seismic mass system)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAbsolute casing vibration velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.5 mV\/mm\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 1000 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNatural Resonance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 Hz +\/-7% at 20 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDamping Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 0.1 at 80 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmplitude Deviation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 2% linearity error\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Displacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 mm peak-to-peak amplitude limit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAcceleration Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous 10 g \/ Intermittent 20 g maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Cross-Axis Acceleration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 g maximum transverse load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal mounting alignment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +200 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC voltage proportional to vibration velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional ATEX certified variants for hazardous zones\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Generating Signal Engine Requires No External Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal coil-and-magnet assembly generates its own voltage signal directly from mechanical motion. This design simplifies field deployment by eliminating the need for external power supplies or charge amplifiers over long field cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliant Low-Frequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA finely tuned 14 Hz natural frequency combined with a stable 0.6 damping factor ensures flat, linear data collection across the vital 10 to 1000 Hz industrial vibration spectrum, matching all criteria for standardized machinery safety systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Thermal Tolerances for Direct Turbine Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rugged internal components withstand sustained operating temperatures ranging from -30 up to +200 degrees Celsius. This permits direct attachment to hot steam turbine cases and high-pressure compressor hoods without risk of sensitivity degradation or coil insulation melting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrict Structural Linearity and Cross-Axis Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal mechanical guides limit cross-axis transverse sensitivity to less than 0.1 at 80 Hz. This guarantees that the probe isolates and reports true horizontal forces while rejecting secondary perpendicular shaft rumble or cross-coupled structural noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the specific mechanical difference between the R9268\/301-000 and other variants in the R9268 line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe R9268\/301-000 features internal suspension springs and mass guides calibrated exclusively for horizontal orientation. You must mount this specific model within its designated horizontal plane. Installing it vertically will misalign the internal coil within the magnetic gap, causing measurement errors and accelerating mechanical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module connect directly into competitive machinery protection racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the R9268\/301-000 outputs a standardized, self-generated raw AC voltage signal rated at 17.5 mV\/mm\/s, it interfaces cleanly with EPRO MMS 6000 racks as well as any alternative industrial monitoring system or PLC analog input card that accepts standard velocity transducer signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you secure this sensor onto the machine casing to avoid signal attenuation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must secure the sensor using a rigid, high-mass mounting bracket or bolt it directly to a flat, machined surface on the bearing housing. Any mechanical compliance, loose fitting, or structural resonance inside the intermediate bracket will damp or distort high-frequency signals, generating inaccurate vibration velocity data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Epro","offers":[{"title":"Default Title","offer_id":43880503246947,"sku":"R9268\/301-000","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/51.1_d3bfb4c1-f80e-4723-b190-8b2610aff9ce.jpg?v=1765268917","url":"https:\/\/www.autocontrolglobal.com\/products\/r9268-301-000-epro-electrodynamic-velocity-sensor","provider":"AutoControl Global","version":"1.0","type":"link"}