{"product_id":"ref615e_e-abb-hbfhaeagnba1ann11e-feeder-protection-relay","title":"REF615E_E ABB HBFHAEAGNBA1ANN11E Feeder Protection Relay","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe REF615E_E HBFHAEAGNBA1ANN11E delivers dedicated feeder protection for various grounding systems and network configurations. It captures real-time electrical parameters to execute high-speed tripping during faults, while simultaneously offering remote switching and auto-reclosing capabilities to improve network availability. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original factory-sealed packaging, ensuring the hardware meets all Finnish manufacturing quality standards for critical power infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF615E_E HBFHAEAGNBA1ANN11E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelion® 615 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvercurrent (50\/51), Earth Fault (50N\/51N), Directional (67), Breaker Failure (50BF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFeeder Control, Remote Switching, Auto-Reclosing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850, Modbus, DNP3, SPA, LON\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC \/ 100-240 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm × 150 mm × 200 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel-mounted (Flush mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe REF615E_E HBFHAEAGNBA1ANN11E provides mechanical and digital solutions for modern power distribution challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative IEC 61850 Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe relay supports GOOSE (Generic Object Oriented Substation Event) messaging. This enables high-speed horizontal communication between relays, eliminating physical inter-bay wiring and significantly reducing commissioning costs for automated substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirectional Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard relays, this unit features directional protection. It distinguishes between upstream and downstream faults, allowing engineers to isolate specific fault zones without shutting down the entire distribution ring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Environmental Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperating flawlessly from –40°C to +70°C, the REF615E_E thrives in unheated substation kiosks and harsh industrial environments where fluctuating temperatures often degrade standard electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Programming \u0026amp; Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsers can customize protection curves and logic using the Application Configuration Tool. This flexibility allows the relay to adapt to changing grid conditions or specific industrial load profiles without hardware replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this relay support fiber optic communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe REF615E_E supports various communication modules. Depending on the specific HBFHAEAGNBA1ANN11E internal hardware configuration, you can utilize RJ45 or Fiber Optic ports for IEC 61850 or Modbus protocols. Please verify your communication hardware requirements prior to installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the unit compatible with retrofitting older substations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Its compact panel-mount design facilitates easy integration into existing control cabinets. The relay’s support for legacy protocols like Modbus, SPA, and LON ensures compatibility with older SCADA systems while providing a pathway to modern IEC 61850 digitization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the auto-reclosing function improve reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn many medium-voltage applications, faults are transient (e.g., bird strikes or falling branches). The REF615E_E can automatically re-energize the feeder after a temporary fault trip, significantly reducing manual service calls and improving the SAIDI (System Average Interruption Duration Index) for utility operators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required for the HBFHAEAGNBA1ANN11E?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model utilizes a universal power supply module, accepting any voltage between 100–240 V AC or 100–240 V DC. This wide input range ensures stability despite voltage fluctuations in industrial power grids.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43788892143715,"sku":"REF615E_E HBFHAEAGNBA1ANN11E","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/190_60ae3e60-0eac-45c0-b4b8-0b3bfa82c6a8.jpg?v=1761040832","url":"https:\/\/www.autocontrolglobal.com\/products\/ref615e_e-abb-hbfhaeagnba1ann11e-feeder-protection-relay","provider":"AutoControl Global","version":"1.0","type":"link"}