{"product_id":"s9343fa-yokogawa-prosafe-rs-esb-bus-termination-unit","title":"S9343FA Yokogawa ProSafe-RS ESB Bus Termination Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa S9343FA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specialized Electronic Serial Bus (ESB) termination unit for the ProSafe-RS Safety Instrumented System (SIS). This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector maintains the electrical integrity of high-speed safety communication by preventing signal reflection and bus noise. In safety-critical architectures, the S9343FA acts as the final impedance-matching component, ensuring that emergency shutdown (ESD) and fire and gas (F\u0026amp;G) logic execute across the ESB bus without data corruption. It provides the physical and electrical stability required for systems operating under rigorous IEC 61508 SIL 3 standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS9343FA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSafe-RS Safety Instrumented System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus Termination and Stabilization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61508 SIL 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISO 13849-1 Category 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mm × 90 mm × 30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, FCC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Reflection Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe S9343FA matches the characteristic impedance of the ESB bus. This eliminates signal \"bounce back\" at the end of the cable run, which otherwise causes data errors and system timeouts in high-speed safety networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 Certified Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered specifically for life-safety applications, this unit meets the stringent requirements of IEC 61508 SIL 3. It guarantees stable communication in environments where fail-safe performance is mandatory, such as offshore platforms and refinery units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Thermal Operating Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust hardware handles extreme temperatures ranging from –20°C to +70°C. This allows for installation in non-climate-controlled local equipment rooms (LER) or remote instrument enclosures in harsh climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined SIS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact, lightweight design facilitates easy mounting within high-density safety racks. It integrates seamlessly with ProSafe-RS modules, providing a clean termination point that simplifies cable management and troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does my ProSafe-RS system require the S9343FA?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn unterminated ESB bus creates electrical noise and signal distortion. The S9343FA provides the necessary termination to ensure that safety controllers and I\/O nodes communicate reliably at high speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the S9343FA in hazardous area enclosures?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Yokogawa designs the S9343FA for industrial and hazardous area environments. When installed in an appropriately rated enclosure (such as NEMA 4X or IP66), it provides reliable safety bus termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the terminator is missing or damaged?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA missing or faulty S9343FA typically triggers bus communication errors or safety system alarms. Replacing a damaged unit with a Brand New S9343FA restores the electrical balance of the ESB bus and clears communication faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Yokogawa Japan product?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original Yokogawa S9343FA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. Each unit undergoes strict quality control to meet the global safety standards required for ProSafe-RS systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43753003057251,"sku":"S9343FA","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/67_80c25627-00e2-491d-9fb1-a89c146157f4.jpg?v=1775697669","url":"https:\/\/www.autocontrolglobal.com\/products\/s9343fa-yokogawa-prosafe-rs-esb-bus-termination-unit","provider":"AutoControl Global","version":"1.0","type":"link"}