{"product_id":"s9564fa-yokogawa-esb-bus-connector-unit-with-terminator","title":"S9564FA Yokogawa ESB Bus Connector Unit with Terminator","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa S9564FA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specialized Electronic Serial Bus (ESB) interface and termination module for the ANB10D Node Unit. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit facilitates high-speed communication between the Field Control Unit (FCU) and distributed I\/O modules. By integrating a precision termination resistor, the S9564FA eliminates signal reflections that cause data corruption in complex bus architectures. It stabilizes the communication network within Yokogawa CENTUM VP and ProSafe-RS platforms, ensuring that critical process data reaches the controller without latency or distortion.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS9564FA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus Connection \u0026amp; Impedance Termination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNode Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa ANB10D (ESB Bus Node Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP and ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminator Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in High-Stability Resistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120V AC \/ 220–240V AC \/ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19-inch Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (Base Unit Only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Loaded Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 10 kg (Fully populated with I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe S9564FA incorporates a high-precision internal terminator. This hardware-level termination matches the bus impedance perfectly, suppressing the \"echo\" effect of high-frequency pulses across long ESB cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined System Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit combines the connection port and the terminator into a single chassis. This design reduces the number of separate components in the cabinet, simplifying the wiring layout and decreasing the risk of accidental disconnection or loose terminators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa engineers the S9564FA to withstand the electromagnetic interference (EMI) prevalent in power plants and chemical refineries. The unit maintains clean data throughput even when situated near high-voltage switchgear or variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Power Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports various power configurations, including 24V DC for battery-backed systems and universal AC inputs. This flexibility allows global deployment across different regional power standards without requiring external transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhen must I use the S9564FA on an ANB10D node?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must install the S9564FA at the end of an ESB bus segment. The built-in terminator prevents the signal from reflecting back into the bus, which is mandatory for maintaining the high-speed data integrity required by CENTUM VP controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the S9564FA support the ProSafe-RS safety system?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The S9564FA maintains full compatibility with both CENTUM VP (DCS) and ProSafe-RS (SIS) architectures, provided you utilize the ANB10D node unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap the S9564FA?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause the S9564FA acts as the bus terminator, removing it while the system is active will disrupt the ESB bus communication for all downstream modules. We recommend performing replacements during scheduled maintenance or following strict Yokogawa safety protocols for live systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Yokogawa product?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. We provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original Yokogawa S9564FA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in their original factory packaging to guarantee compliance with your system's warranty and safety specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43753012428899,"sku":"S9564FA","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/68_fdb98f8c-91c0-402c-9577-17c3d45e1112.jpg?v=1775698088","url":"https:\/\/www.autocontrolglobal.com\/products\/s9564fa-yokogawa-esb-bus-connector-unit-with-terminator","provider":"AutoControl Global","version":"1.0","type":"link"}