{"product_id":"safety-manager-digital-output-fta-honeywell-fc-tdol-0724","title":"Safety Manager Digital Output FTA | Honeywell FC-TDOL-0724","description":"\u003ch2\u003eHoneywell FC-TDOL-0724 CC V1.0 Digital Output FTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for relay contact switching and field wiring supervision in Honeywell Safety Manager systems, the \u003cstrong\u003eHoneywell FC-TDOL-0724 CC V1.0\u003c\/strong\u003e (\u003cstrong\u003eFC-TDOL-0724\u003c\/strong\u003e) Line-Monitored Digital Output Field Termination Assembly provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TDOL-0724 CC V1.0 \/ FC-TDOL-0724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm x 109 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply (+30% \/ -15% tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e7 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003e2 A slow-acting fuse per channel (5 x 20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Load\u003c\/td\u003e\n\u003ctd\u003e50 W per channel (Resistive and inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Monitoring\u003c\/td\u003e\n\u003ctd\u003eOpen-circuit and short-circuit fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Output Module\u003c\/td\u003e\n\u003ctd\u003eSDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Input Module\u003c\/td\u003e\n\u003ctd\u003eSDI-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eSeven pairs of screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connector\u003c\/td\u003e\n\u003ctd\u003e2-pole common supply connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN EN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Galvanic Line Monitoring\u003c\/h3\u003e\n\u003cp\u003eEngineering integration into DCS loop architecture relies on galvanic isolation across individual output channels to isolate transient ground loops and maintain baseline signal purity. The termination assembly incorporates dedicated line-monitoring circuitry that continuously senses current leakages up to 1.1 mA across a maximum load resistance of 2,200 ohm. Internal diagnostic circuits detect open-circuit conditions and shorted field wiring without dropping loop excitation. Cold junction compensation and galvanic signal separation preserve safety loop integrity during heavy inductive switching operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the channel line monitoring function without tripping connected load devices?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic network drives a low-level sensing current of approximately 1.1 mA at 24 VDC across the field loop, evaluating line resistance up to 2,200 ohm to detect open or short faults without activating downstream field devices.\u003c\/p\u003e\n\u003cp\u003eQ: What fuse specification is required for individual output channel protection?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel requires a 5 x 20 mm, 2 A slow-acting fuse to clear overcurrent fault conditions caused by external wiring shorts or severe field surges.\u003c\/p\u003e\n\u003cp\u003eQ: Which Safety Manager module interfaces directly with this field termination assembly?\u003c\/p\u003e\n\u003cp\u003eA: The module connects directly to the SDO-0824 digital output module and SDI-1624 digital input module through system interface cabling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a standard DIN EN rail inside a grounded metal enclosure. Maintain a minimum vertical clearance of 50 mm above and below the housing to facilitate natural thermal convection up to the 70 deg C maximum operating threshold. Wire incoming system power through the dedicated 2-pole supply connector using 24 VDC nominal loop conductors. Connect field wiring to the seven screw terminal pairs, torquing terminals to 0.5 Nm. Ground all field cable shields at a single earth point near the cable gland plate to prevent ground loop current paths.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67741162930275,"sku":"FC-TDOL-0724 CC V1.0","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/652_e26c356b-38b8-4a14-94cb-3c40c40c45aa.jpg?v=1792376601","url":"https:\/\/www.autocontrolglobal.com\/products\/safety-manager-digital-output-fta-honeywell-fc-tdol-0724","provider":"AutoControl Global","version":"1.0","type":"link"}