{"product_id":"safety-manager-termination-assembly-honeywell-fs-tsro-0824","title":"Safety Manager Termination Assembly | Honeywell FS-TSRO-0824","description":"\u003ch2\u003eHoneywell FS-TSRO-0824 Digital Output Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSRO-0824\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-TSRO-0824\u003c\/strong\u003e Digital Output Field Termination Assembly, operates as a dedicated hardware component for managing eight floating, non-commoned output channels within Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSRO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg to 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 mm x 70 mm x 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 mA at 24 VDC (Typical Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Floating, Non-Commoned Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ratings\u003c\/td\u003e\n\u003ctd\u003e250 V Max Output, 5 A Fused NO Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fault-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eDesigned in compliance with rigorous safety instrumented standards, the assembly achieves SIL3 certification to guarantee dependable fail-safe state execution during critical process upsets. Galvanic isolation between field loops and internal control architecture prevents common-mode voltage transfer and ground loops across hazardous areas. Furthermore, integrated triple modular redundancy compatibility and isolated relay configurations ensure that single-fault conditions never compromise safety shutdown loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input voltage and current characteristics of the FS-TSRO-0824 assembly?\u003c\/p\u003e\n\u003cp\u003eA: The unit operates at a nominal input voltage of 24 VDC with a maximum input limit of 36 VDC, drawing an input current of approximately 40 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How are field-side relay contacts protected against overcurrent conditions?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates fused normally open field contacts rated for 5 A slow-acting protection across all eight output channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the hardware provide visual status indication for individual channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the assembly features dedicated per-channel LED indicators to provide real-time diagnostic feedback regarding relay and output states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the termination assembly securely onto standard structural mounting rails within the safety control cabinet. Ensure proper grounding of all shielded field wiring using low-impedance clamps connected directly to the cabinet ground bar. Verify that all 24 VDC power feeds and high-voltage field wiring terminals are tightened correctly prior to system energization. Maintain adequate physical separation from high-power conduits to prevent induced electromagnetic interference across safety-critical loops.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43796228079715,"sku":"FS-TSRO-0824","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/540_5ca95a1c-c135-4148-adc8-9c3be72a8b79.jpg?v=1761622035","url":"https:\/\/www.autocontrolglobal.com\/products\/safety-manager-termination-assembly-honeywell-fs-tsro-0824","provider":"AutoControl Global","version":"1.0","type":"link"}