Safety System Circuit Breaker | HIMA ETA2210 4A H7201
Safety System Circuit Breaker | HIMA ETA2210 4A H7201
Safety System Circuit Breaker | HIMA ETA2210 4A H7201
/ 3

Safety System Circuit Breaker | HIMA ETA2210 4A H7201

  • Manufacturer: HIMA

  • Part Number: ETA2210 4A H7201

  • Condition:New with Original Package

  • Product Type: Miniature Circuit Breakers

  • Country of Origin: Germany

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

HIMA ETA2210 4A H7201 Thermal-Magnetic Circuit Breaker

The HIMA ETA2210 4A H7201, also cataloged as the ETA2210 Thermal-Magnetic Circuit Breaker, operates as a dedicated hardware component for overcurrent protection within HIMA safety system power distribution circuits.

Hardware Specifications

Parameter Specification
Model ETA2210 4A H7201
Brand HIMA
Origin Germany
Component Type Thermal-Magnetic Circuit Breaker
Rated Current 4 A
Voltage Rating Up to 250 VAC / 65 VDC
Trip Mechanism Trip-free toggle (thermal and magnetic)
Mounting Style Panel Mount
Terminal Type Recessed screw terminals
Auxiliary Contacts Optional (1 NO or 1 NC)
Weight 0.2 kg
Dimensions Height 100 mm
Operating Temp Standard cabinet environment limits
Power Consumption Passive Component
Protection Standard EN 60934 / IEC 60934
Certifications CE, UL, FCC

Functional Safety & Overcurrent Protection Attributes

The unit provides instantaneous magnetic trip execution for high-current short circuits and timed thermal tripping for sustained low-level overloads, enforcing critical circuit safety across logic supply lines. The trip-free toggle mechanism prevents manual overrides during active electrical faults, ensuring positive contact opening and deterministic fail-safe state execution. Galvanic isolation across open contacts protects connected logic racks and downstream field instruments from overcurrent degradation.

Frequently Asked Questions

Q: How does the trip-free toggle mechanism ensure system safety during an active fault?

A: The internal latch mechanism forces the contacts to open during overcurrent conditions, preventing operators from manually forcing or holding the switch in the ON position during a persistent electrical fault.

Q: Can the optional auxiliary contacts be integrated into control system diagnostic loops?

A: Yes, the optional 1 NO or 1 NC auxiliary contact provides dedicated potential-free status feedback to indicate circuit breaker trip conditions directly to system monitoring hardware.

Field Installation Guidelines

Execute the following steps during panel construction and electrical wiring:

  1. Mount the unit securely onto the panel cutout using designated panel-mount hardware.
  2. Strip control wiring conductors to standard length and insert them into the recessed screw terminals.
  3. Torque all terminal connections securely to prevent localized heat buildup caused by loose contact resistance.
  4. Verify that supply line operating parameters do not exceed 250 VAC or 65 VDC prior to closing the circuit.
  5. Wire optional auxiliary status contact circuits into separate low-voltage diagnostic channels using segregated cable routing.
You may also like