{"product_id":"sai533-h63-prp-s1-yokogawa-prp-analog-output-module","title":"SAI533-H63\/PRP S1 | Yokogawa | PRP Analog Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYokogawa SAI533-H63\/PRP S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a current output module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Field I\/O (FIO) system\u003c\/strong\u003e, providing stable and accurate 4–20 mA analog output signals to field devices. The module is intended for use in high-availability control architectures and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePRP (Parallel Redundancy Protocol)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure uninterrupted communication at the network level.\u003c\/p\u003e\n\u003cp\u003eThis module is suitable for controlling valves, actuators, and other final control elements in mission-critical process automation environments where deterministic output behavior and network fault tolerance are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAI533-H63\/PRP S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts controller output data into analog current signals and delivers them to field devices through pressure clamp terminals. PRP support enables seamless network redundancy, allowing parallel Ethernet paths to operate simultaneously without packet loss during network failures.\u003c\/p\u003e\n\u003cp\u003eThe module supports integration into redundant FIO node configurations and provides continuous self-diagnostics to maintain system integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Type: DC analog current output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Channels: 8 output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal Range: 4–20 mA DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad Resistance: Up to 600 Ω (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Accuracy: ±0.1% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eD\/A Conversion Resolution: 16-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule-level isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel-to-system isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Redundancy: PRP (Parallel Redundancy Protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface: ESB bus \/ ER bus via FIO node units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible Node Units: ANB10S, ANB10D, ANT series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signal monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule self-diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: Provided by FIO base unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant Configuration: Supported at system level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: Plug-in FIO module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal Wiring: Pressure clamp terminal connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 5.1 × 25.4 × 11.4 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNet Weight: 0.63 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 10%–90% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Resistance: Conforms to IEC industrial standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43983272312931,"sku":"SAI533-H63\/PRP","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/61._9522a6cb-3d7e-4859-9974-a93e42f9af31.jpg?v=1770083191","url":"https:\/\/www.autocontrolglobal.com\/products\/sai533-h63-prp-s1-yokogawa-prp-analog-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}