{"product_id":"sb301-module-yokogawa-system-backplane-for-industrial-control","title":"SB301 Module | Yokogawa System Backplane for Industrial Control","description":"\u003ch1\u003e\u003cstrong\u003eYokogawa SB301 S1 Interface Card Module – Product Description\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa SB301 S1 is a rack-mounted backplane interface card designed for CENTUM VP DCS and ProSafe‑RS SIS systems. It provides the mechanical and electrical foundation for installing CPUs, I\/O modules, communication cards, and power supplies. Moreover, its high-quality connectors ensure stable communication and reliable power distribution across all connected modules. Therefore, it is ideal for industrial applications requiring mission-critical reliability and redundancy.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBus Type: Proprietary Yokogawa system bus (CENTUM VP and ProSafe‑RS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Modules: CPU (CP401), I\/O (ADV, AMN, NFDR), Communication (AIP, ACM), Power (PW301, PW401)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Distribution: Regulated DC from PW series modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundancy: Supports dual redundant bus configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Integrity: High-quality connectors for low noise and stable communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSlots: 10–12 module slots depending on configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (W × H × D): 482 × 177 × 250 mm (19-inch rack standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 3–5 kg depending on configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Rack-mounted inside system cabinet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling: Natural convection (fanless)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReliability: Continuous 24\/7 operation in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-Swap Capability: Modules can be replaced without shutting down the system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: LED indicators for bus and power status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental \u0026amp; Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertifications: CE, UL, CSA, ATEX (depending on configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: Manufactured in Japan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of modules does SB301 support?\u003c\/strong\u003e\u003cbr\u003eIt supports CPU, I\/O, communication, and power supply modules within Yokogawa systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can SB301 operate redundantly?\u003c\/strong\u003e\u003cbr\u003eYes, it supports dual redundant bus configurations for fault-tolerant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is hot-swap replacement possible for modules?\u003c\/strong\u003e\u003cbr\u003eYes, modules can be inserted or removed without shutting down the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eIt operates between 0 °C and +55 °C for industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Which systems is SB301 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates seamlessly with Yokogawa CENTUM VP DCS and ProSafe‑RS SIS systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43886287093859,"sku":"SB301","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/83.1_9d162c49-1c18-43d5-bec3-fd30f004a53d.jpg?v=1765524812","url":"https:\/\/www.autocontrolglobal.com\/products\/sb301-module-yokogawa-system-backplane-for-industrial-control","provider":"AutoControl Global","version":"1.0","type":"link"}