Schneider 170BNO67100 Modicon Momentum Interbus Module
Manufacturer: Schneider
-
Part Number: 170BNO67100
Condition:New with Original Package
Product Type: Digital I/O Cards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Schneider Electric 170BNO67100 Modicon Momentum Discrete Output Module with Interbus Interface
The Schneider Electric 170BNO67100, also cataloged as the 170BNO67100 Discrete Output Module with Interbus Interface, operates as a dedicated hardware component for high-density digital signal actuation and branch-level communication within Modicon Momentum network architectures.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 170BNO67100 |
| Brand | Schneider Electric |
| Origin | Germany |
| Weight | 0.15 kg |
| Dimensions | 141.5 x 125 x 47.5 mm |
| Operating Temp | Consult Factory |
| Power Consumption | Internal backplane powered |
| Number of Outputs | 32 DC outputs |
| Output Voltage Range | 24 VDC nominal (18 to 30 VDC) |
| Output Current | 0.5 A per channel, 8 A total per module |
| Output Type | Transistor (sourcing) |
Backplane Bus Communication and I/O Density Scaling
The module interfaces directly with the Modicon Momentum backplane bus while integrating an Interbus SUPI 2 branch interface for network communications. Engineers leverage its high I/O density scaling design to pack 32 transistor sourcing outputs into a single compact housing. Furthermore, deterministic backplane bus communication velocity and firmware flash compatibility ensure minimal propagation delay and precise signal synchronization across distributed field actuators.
Frequently Asked Questions
Q: Can the 170BNO67100 be hot-swapped while the Momentum base remains energized?
A: Hot-swapping is restricted while system power and field voltage are active, as electrical transients can damage internal transistor switching components. Always isolate power prior to module extraction.
Q: How does the module handle overcurrent conditions on the transistor outputs?
A: The module's internal circuitry monitors output currents, protecting the solid-state switches against thermal overloads when driving external inductive loads.
Field Installation Guidelines
Mount the module securely onto a standard DIN rail or Momentum baseplate, ensuring mechanical locking latches engage fully. Route 24 VDC power and low-voltage signal lines away from high-voltage alternating current conduits to suppress electromagnetic induction. Terminate cable shields properly to protective earth to preserve signal integrity across the output loops.