{"product_id":"schneider-170xts00100-modicon-terminal-block","title":"Schneider 170XTS00100 Modicon Terminal Block","description":"\u003ch2\u003eSchneider Electric 170XTS00100 Modicon Momentum Terminal Block\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 170XTS00100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e170XTS00100\u003c\/strong\u003e Screw Terminal Block, operates as a dedicated hardware component for physical wiring termination within Modicon Momentum network architectures. It routes field signals directly to modular I\/O points while maintaining secure mechanical and electrical connections.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e170XTS00100\u003c\/strong\u003e: Standard 36-point screw terminal block designed for direct plug-in compatibility across the Modicon Momentum I\/O platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170XTS00100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eConsult Factory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eConsult Factory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e141.5 x 125 x 47.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive wiring component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Terminals\u003c\/td\u003e\n\u003ctd\u003e36 connection points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Capacity\u003c\/td\u003e\n\u003ctd\u003e1 x 2.5 to 2 x 1.5 mm squared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in to Momentum I\/O base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eAlthough the terminal block functions primarily as a passive mechanical and electrical interface, it integrates seamlessly with the high I\/O density scaling design of Modicon Momentum bases. Engineers utilize its 36 connection points to consolidate complex field wiring into a compact physical footprint. Furthermore, strict alignment with backplane bus communication velocity parameters ensures that signal paths remain stable and predictable across connected discrete and analog modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 170XTS00100 terminal block be removed while field power is active?\u003c\/p\u003e\n\u003cp\u003eA: Removing the terminal block while field voltages remain energized is restricted, as unexpected circuit breaks can induce electrical arcs or compromise connected load devices. Always isolate power prior to disconnection.\u003c\/p\u003e\n\u003cp\u003eQ: What conductor cross-section sizes are supported by the screw terminals?\u003c\/p\u003e\n\u003cp\u003eA: The terminals accommodate wiring capacities ranging from single conductors up to 2.5 mm squared or dual conductors up to 1.5 mm squared per clamping point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal block directly onto the front face of the designated Modicon Momentum I\/O base, ensuring that retention screws are tightened evenly to secure the mechanical interface. Strip field conductors to the recommended length before inserting them into the metal screw terminals, and apply appropriate torque to prevent loose connections. Route signal wires away from high-voltage power conduits to suppress electromagnetic interference and protect signal integrity.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43917307150435,"sku":"170XTS00100","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/239_e454e6a8-08dc-4740-971b-d485c864e78d.jpg?v=1766720847","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-170xts00100-modicon-terminal-block","provider":"AutoControl Global","version":"1.0","type":"link"}