{"product_id":"schneider-electric-170anr12091-modicon-momentum-i-o-base","title":"Schneider Electric 170ANR12091 Modicon Momentum I\/O Base","description":"\u003ch2\u003eSchneider Electric 170ANR12091 Modicon Momentum Analog\/Discrete I\/O Base\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 170ANR12091\u003c\/strong\u003e is a mixed-signal I\/O base module designed for the Modicon Momentum distributed automation platform. It combines 6 analog inputs, 4 analog outputs, 8 discrete inputs, and 8 discrete outputs in a single unit. Built for 24 VDC control systems, this base interfaces field sensors and actuators with top-mounted Momentum communication adapters or processors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170ANR12091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Momentum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog\/Discrete I\/O Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e6 single-ended channels (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Signal Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Resolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Analog Input Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Conversion Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.75 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Channels\u003c\/td\u003e\n\u003ctd\u003e4 channels (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Signal Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Resolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Load Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 2 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Conversion Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Conversion Error\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.4 % at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (2 groups of 4), IEC 1131-2 Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (3 to 32 V limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (State 1 \u0026gt;= 11 V \/ \u0026gt;= 6 mA; State 0 \u0026lt;= 5 V \/ \u0026lt;= 2 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Overvoltage\u003c\/td\u003e\n\u003ctd\u003e45 V for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms (state 0 to 1 and state 1 to 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (1 group), positive logic transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.25 A per point, 2 A per group, 2 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Protection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms (state 0 to 1), 1.05 ms (state 1 to 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V for 1 min (between analog I\/O and operating voltage; between operating voltage and I\/O to ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e2 connectors for removable terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signaling\u003c\/td\u003e\n\u003ctd\u003e8 channel status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e141.5 mm x 47.5 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Architecture and Grounding\u003c\/h3\u003e\n\u003cp\u003eThe analog section handles bipolar +\/- 10 VDC voltage signals across 6 single-ended inputs and 4 outputs at 14-bit resolution. Analog outputs provide configurable fail-state behavior, allowing the channel to either hold its last value or reset to zero upon fault detection.\u003c\/p\u003e\n\u003cp\u003eThe discrete section operates on 24 VDC positive logic. The 8 inputs are split into two isolated groups of 4 and meet IEC 1131-2 Type 2 thresholds. The 8 transistor outputs are arranged in a single group rated at 0.25 A per point and 2 A maximum total load, incorporating built-in short-circuit and overload protection.\u003c\/p\u003e\n\u003cp\u003eInternally, analog ground (AGND) and digital ground (DGND) tie together at a single common point inside the base. Field wiring must strictly observe this separation: external digital input circuits return to the DGND terminal, while external analog circuits return to AGND terminals to prevent ground loops and signal noise.\u003c\/p\u003e\n\u003ch3\u003eWiring and Platform Integration\u003c\/h3\u003e\n\u003cp\u003eThe 170ANR12091 forms the lower hardware layer of a Modicon Momentum node and requires a snap-on top adapter—such as a fieldbus communication adapter or processor module—to communicate with a host controller.\u003c\/p\u003e\n\u003cp\u003eField wiring connects through two front-facing ports designed for removable terminal blocks. Per manufacturer wiring diagrams, external fusing is specified for circuit protection: 1 A fuses on power\/analog supply lines (F1, F3) and a 2.5 A fuse on the discrete output supply line (F2).\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Does the 170ANR12091 support 4-20 mA current signals on its analog channels? A: No. Both the 6 analog inputs and 4 analog outputs are hardware-configured strictly for +\/- 10 VDC voltage signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 170ANR12091 operate as a standalone remote I\/O station without additional hardware? A: No. As an I\/O base module, it requires a compatible Modicon Momentum communication adapter or processor snapped onto its top connector, as well as removable terminal blocks for field wiring.\u003c\/p\u003e\n\u003cp\u003eQ: How should analog and discrete ground wires be terminated on this module?A: External analog circuits must return exclusively to the AGND terminals, and external digital inputs must return to the DGND terminal. Although AGND and DGND connect internally at a single point, keeping field returns separate prevents digital switching noise from affecting analog accuracy.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67956628062307,"sku":"170ANR12091","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/316._ec890649-c1e0-469e-b7e3-a89e5a65be3e.jpg?v=1795049972","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-170anr12091-modicon-momentum-i-o-base","provider":"AutoControl Global","version":"1.0","type":"link"}