{"product_id":"schneider-electric-abl8rps24050-phaseo-120w-power-supply","title":"Schneider Electric ABL8RPS24050 Phaseo 120W Power Supply","description":"\u003ch2\u003eSchneider Electric ABL8RPS24050 Phaseo Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eABL8RPS24050\u003c\/strong\u003e is a 120 W regulated switch-mode power supply in the Phaseo series, providing 24 VDC at 5 A for PLC, sensor, relay, and actuator circuits. It accepts wide single-phase (100-120 VAC) or phase-to-phase (200-500 VAC) AC inputs as well as 110-220 VDC. Key capabilities include 24-28.8 VDC output adjustment, a 1.5 x In (7.5 A) 4-second boost, and parallel or series output coupling.\u003c\/p\u003e\n\u003ch3\u003eInput Flexibility and Output Performance\u003c\/h3\u003e\n\u003cp\u003eDual-range AC input limits of 85-132 VAC and 170-550 VAC (47-63 Hz) allow connection to standard single-phase mains or 400\/480 VAC phase-to-phase industrial distribution without step-down transformers. An integrated low-frequency anti-harmonic \/ PFC filter manages line harmonics, with inrush current capped at 30 A for 2 ms and efficiency reaching 87% (15.5 W dissipation).\u003c\/p\u003e\n\u003cp\u003eOn the load side, the 24 VDC output adjusts up to 28.8 VDC to compensate for cable voltage drop while maintaining 1-3% line and load regulation and up to 200 mV residual ripple. Short-term peak loads are supported by a 150% (7.5 A) boost for 4 s, and outputs can be coupled in parallel or series.\u003c\/p\u003e\n\u003ch3\u003eProtection Thresholds and Mechanical Details\u003c\/h3\u003e\n\u003cp\u003eBuilt-in electronic protection covers overload, short-circuit, thermal fault, overvoltage (30-32 VDC), and undervoltage shutdown (below 21.6 VDC). The 143 x 56 x 125 mm (H x W x D) unit weighs 0.7 kg and mounts on a 35 mm DIN rail or panel, running without derating up to +45 deg C and with derating up to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABL8RPS24050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePhaseo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRegulated Switch-Mode Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC (single-phase), 200-500 VAC (phase-to-phase), 110-220 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC, 170-550 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eUp to 30 A (for 2 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.51 at 240 VAC, 0.59 at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Filtering\u003c\/td\u003e\n\u003ctd\u003eIntegrated anti-harmonic \/ PFC filter (low-frequency harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e15.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporary Current Boost\u003c\/td\u003e\n\u003ctd\u003e1.5 x In \/ 150% (7.5 A) for 4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine and Load Regulation\u003c\/td\u003e\n\u003ctd\u003e1-3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Ripple\u003c\/td\u003e\n\u003ctd\u003eUp to 200 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Coupling\u003c\/td\u003e\n\u003ctd\u003eParallel or series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eOverload, short-circuit, thermal, overvoltage (30-32 VDC), undervoltage (shutdown below 21.6 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +45 deg C no derating, up to +60 deg C with derating (-25 to +60 deg C listed in second source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e143 x 56 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cp\u003eQ: Can the ABL8RPS24050 be wired directly to a 400 VAC or 480 VAC two-phase supply? A: Yes, its phase-to-phase input is rated for 200-500 VAC nominal (170-550 VAC limits, 47-63 Hz), alongside 100-120 VAC single-phase and 110-220 VDC inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ABL8RPS24050 support parallel or series output wiring? A: Yes, the output stage supports both parallel and series coupling configurations.\u003c\/p\u003e\n\u003cp\u003eQ: What overvoltage and undervoltage trip levels apply to the 24 VDC output? A: Overvoltage protection triggers at 30-32 VDC, and undervoltage protection shuts down the output below 21.6 VDC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43883596054627,"sku":"ABL8RPS24050","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/394._24791f51-2e5a-4761-b925-8f0ebade081b.jpg?v=1795173818","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-abl8rps24050-phaseo-120w-power-supply","provider":"AutoControl Global","version":"1.0","type":"link"}