{"product_id":"schneider-electric-bmxddo6402kru-discrete-output-module","title":"Schneider Electric BMXDDO6402KRU Discrete Output Module","description":"\u003ch2\u003eSchneider Electric BMXDDO6402KRU Modicon X80 Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXDDO6402KRU\u003c\/strong\u003e is a 64-channel positive-logic discrete transistor output module for the Modicon X80 platform. Rated for 24 V DC nominal output (19-30 V DC operating range) with 0.1 A rated current per channel and a 1.2 ms response time, it connects via two 40-pin connectors and features conformal coating for ruggedized deployment.\u003c\/p\u003e\n\u003ch3\u003eOutput Channels, Wiring, and Paralleling\u003c\/h3\u003e\n\u003cp\u003eHigh-density solid-state transistor outputs allow a Modicon X80 controller to drive external loads such as relays, solenoid valves, contactors, and indicator lamps. Each channel is rated at 0.1 A with a maximum current of 0.125 A and a total module output limit of 6.4 A.\u003c\/p\u003e\n\u003cp\u003eUp to 3 outputs can be paralleled when higher load current is needed within the module and circuit limits. Field connections use two 40-pin connectors, and short-circuit protection requires an external 2 A fuse.\u003c\/p\u003e\n\u003ch3\u003eProtection and Electrical Ratings\u003c\/h3\u003e\n\u003cp\u003eBuilt-in protection includes an electronic current limiter and circuit breaker for overload conditions, a Transil diode for overvoltage suppression, and a reverse-mounted diode for reverse-polarity protection. Conformal coating on the RU variant provides added protection against environmental contaminants alongside IP20 housing protection.\u003c\/p\u003e\n\u003cp\u003eInternal logic draw is 160 mA at 3.3 V DC with 6.85 W power dissipation and greater than 10 MOhm insulation resistance at 500 V DC. The module conforms to EN\/IEC 61131-2.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDDO6402KRU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Transistor Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Current\u003c\/td\u003e\n\u003ctd\u003e6.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Paralleling\u003c\/td\u003e\n\u003ctd\u003eUp to 3 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eTwo 40-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic current limiter and circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eExternal 2 A fuse required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eTransil diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eReverse-mounted diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating (RU variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external protection is required for short-circuit protection on the \u003cstrong\u003eBMXDDO6402KRU\u003c\/strong\u003e? A: An external 2 A fuse is required for short-circuit protection, alongside the module's built-in electronic current limiter, circuit breaker, Transil overvoltage diode, and reverse-polarity diode.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels on the \u003cstrong\u003eBMXDDO6402KRU\u003c\/strong\u003e be combined for higher current loads? A: Yes, up to 3 outputs can be paralleled while staying within per-channel and overall module current limits.\u003c\/p\u003e\n\u003cp\u003eQ: What operating voltage range does the 24 V DC output stage support? A: The rated output voltage is 24 V DC with an operating voltage range of 19-30 V DC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67994303266915,"sku":"BMXDDO6402KRU","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/411._66c47120-f36d-466f-9aed-8f349e1e3616.jpg?v=1795422322","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-bmxddo6402kru-discrete-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}