{"product_id":"schneider-electric-c65h-dcc10a-multi-9-dc-miniature-circuit-breaker","title":"Schneider Electric C65H-DCC10A Multi 9 DC Miniature Circuit Breaker","description":"\u003ch2\u003eSchneider Electric C65H-DCC10A Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eConfigured for overcurrent protection in low-voltage DC distribution networks, the \u003cstrong\u003eSchneider Electric C65H-DCC10A\u003c\/strong\u003e (\u003cstrong\u003eC65H-DCC10A\u003c\/strong\u003e Miniature Circuit Breaker) provides direct physical execution of thermal-magnetic fault isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eC65H-DCC10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e84 x 36 x 73.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial control and I\/O density scaling\u003c\/h3\u003e\n\u003cp\u003eThe C65H-DCC10A module integrates into DC power distribution panels, where the thermal-magnetic trip mechanism responds to fault currents within deterministic time-current envelopes. In high-density industrial control architectures, the 36 mm width per 2-pole unit allows for efficient I\/O density scaling, optimizing panel space while maintaining circuit segregation. The device maintains compatibility with standard DIN-rail mounting protocols, ensuring structural stability when subjected to the mechanical stresses inherent in high-vibration control environments. Its operational parameters align with fixed firmware flash compatibility requirements for automated power management, providing predictable trip characteristics during transient inrush events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the C65H-DCC10A require specific orientation for DIN-rail mounting?\u003c\/p\u003e\n\u003cp\u003eA: The breaker is designed for vertical mounting on a 35 mm DIN rail. Ensure the device is installed in the upright position to allow for proper thermal convection and to maintain the integrity of the thermal-magnetic tripping mechanism.\u003c\/p\u003e\n\u003cp\u003eQ: Is this device compatible with AC power distribution circuits?\u003c\/p\u003e\n\u003cp\u003eA: No, this unit is engineered exclusively for DC applications. Utilizing this circuit breaker in an AC circuit will cause improper quenching of the arc during interruption, leading to premature device failure or safety hazards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Snap the circuit breaker onto a 35 mm DIN rail. Ensure the locking latch is fully engaged to prevent longitudinal movement or accidental detachment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e: Strip conductors to the appropriate length for the tunnel terminals. Insert the cable (1–25 mm squared) and secure with a torque of 2.5 N m to prevent heating at the connection point due to contact resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Observation\u003c\/strong\u003e: Observe proper input\/output polarity markings as indicated on the device housing. Incorrect wiring of the DC circuit may compromise the breaker's ability to extinguish the arc during a fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Verification\u003c\/strong\u003e: Before energizing, use a multimeter to verify the absence of short circuits on the load side. Confirm the DC source voltage is within the rated 250 V DC threshold to ensure safe operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43865619693667,"sku":"C65H-DCC10A","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/4_598e79f0-7e42-4a67-86de-060ffa796cd3.jpg?v=1764572273","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-c65h-dcc10a-multi-9-dc-miniature-circuit-breaker","provider":"AutoControl Global","version":"1.0","type":"link"}