{"product_id":"schneider-electric-mnb-cntlr-1000-tac-micronet-plant-controller","title":"Schneider Electric MNB-CNTLR-1000 TAC MicroNet Plant Controller","description":"\u003ch2\u003eSchneider Electric MNB-CNTLR-1000 MicroNet BACnet Plant Controller Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMNB-CNTLR-1000\u003c\/strong\u003e is an I\/O controller subassembly designed for the TAC I\/A Series MicroNet BACnet MNB-1000 plant controller system. Operating on a 24 VAC power supply, it acts as the processing unit within building automation and HVAC management systems, executing programmable control sequences for equipment such as air-handling units and cooling towers.\u003c\/p\u003e\n\u003ch3\u003eI\/O and System Capacity\u003c\/h3\u003e\n\u003cp\u003eThis controller subassembly provides comprehensive onboard input and output channels to interface with field devices. It supports 12 universal inputs, 4 digital inputs, 8 universal outputs, and 8 digital Triac outputs. Configuration and control logic development are performed using WorkPlace Tech programming software.\u003c\/p\u003e\n\u003ch3\u003eIntegration and Communication\u003c\/h3\u003e\n\u003cp\u003eNetwork connectivity is established via an RS-485 serial interface operating on the BACnet MS\/TP protocol. For room sensor integration, the unit features an S-Link (Sensor Link) interface, and it supports system expansion using remote I\/O modules. The assembly mounts directly onto the standard MNB-1000 controller base.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMNB-CNTLR-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eTAC I\/A Series MicroNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Controller Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Platform\u003c\/td\u003e\n\u003ctd\u003eMNB-1000 BACnet Plant Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eBuilding Automation \/ HVAC Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Supply Range\u003c\/td\u003e\n\u003ctd\u003e20.4–30 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 MS\/TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 Triac outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Interface\u003c\/td\u003e\n\u003ctd\u003eSensor Link (S-Link)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eWorkPlace Tech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMNB-1000 controller base assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Is the MNB-CNTLR-1000 a complete standalone controller? A: No, the MNB-CNTLR-1000 is the controller subassembly itself and requires the MNB-1000 base assembly for installation and field connection.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range is required for operation? A: It operates on a 24 VAC nominal supply with an acceptable voltage range of 20.4 to 30 VAC at 50\/60 Hz.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67901151805539,"sku":"MNB-CNTLR-1000","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/262._2c289209-e23f-4520-bb22-fa31f7b8bb54.jpg?v=1794299356","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-mnb-cntlr-1000-tac-micronet-plant-controller","provider":"AutoControl Global","version":"1.0","type":"link"}