{"product_id":"schneider-electric-tsxasy800-modicon-premium-output-module","title":"Schneider Electric TSXASY800 Modicon Premium Output Module","description":"\u003ch2\u003eSchneider Electric TSXASY800 Modicon Premium Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXASY800\u003c\/strong\u003e is an 8-channel analog output module for the Modicon Premium PLC platform. It generates current and voltage signals across 0–20 mA, 4–20 mA, and +\/-10 V ranges with 13-bit plus sign resolution and a 5 ms conversion time, connecting field devices via a 25-pin SUB-D connector and common-point channel architecture.\u003c\/p\u003e\n\u003ch3\u003eSignal Ranges and Conversion Performance\u003c\/h3\u003e\n\u003cp\u003eResolution reaches 1.28 mV for voltage outputs and 2.56 uA for current outputs across a 5 ms conversion cycle. Because all eight channels share a common-point reference rather than individual channel-to-channel isolation, loop wiring and ground references must be planned carefully when driving multiple field actuators.\u003c\/p\u003e\n\u003cp\u003eCurrent loops support load impedance less than 600 ohm, while voltage outputs require load impedance greater than 1000 ohm to limit voltage drop. Output protection includes short-circuit and overload protection, a maximum output voltage limit of 30 V, a maximum load inductance of 300 uH, and a maximum load capacitance of 0.1 uF.\u003c\/p\u003e\n\u003ch3\u003eRack Power and Field Connection\u003c\/h3\u003e\n\u003cp\u003eThe module mounts in a Modicon Premium PLC rack and draws 200 mA at 5 V DC plus 300 mA at 24 V DC from the system supply. Isolation is rated at 1000 Vrms to both the bus and ground, and field wiring terminates on a 25-pin SUB-D connector.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXASY800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVoltage \/ Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Conversion Resolution\u003c\/td\u003e\n\u003ctd\u003e13 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Resolution\u003c\/td\u003e\n\u003ctd\u003e1.28 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Resolution\u003c\/td\u003e\n\u003ctd\u003e2.56 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation to Bus\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation to Ground\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance (Current)\u003c\/td\u003e\n\u003ctd\u003eLess than 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance (Voltage)\u003c\/td\u003e\n\u003ctd\u003eGreater than 1000 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Inductance\u003c\/td\u003e\n\u003ctd\u003e300 uH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e0.1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e25-pin SUB-D connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 V DC Current Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V DC Current Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModicon Premium PLC rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What load impedance limits apply to the current and voltage outputs on the TSXASY800? A: Current outputs require load impedance less than 600 ohm, while voltage outputs require load impedance greater than 1000 ohm. Field wiring must also stay within 300 uH maximum load inductance and 0.1 uF maximum load capacitance.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TSXASY800 isolate each analog output channel from the others? A: No, channels use a common-point configuration rather than individual channel-to-channel isolation. The module provides 1000 Vrms isolation to the bus and to ground.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68019926630499,"sku":"TSXASY800","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/338.1_ca64e396-487e-4af3-9169-7d627b898fa6.jpg?v=1795764682","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-tsxasy800-modicon-premium-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}