{"product_id":"schneider-electric-tsxdey08d2-modicon-premium-input-module","title":"Schneider Electric TSXDEY08D2 Modicon Premium Input Module","description":"\u003ch2\u003eSchneider Electric TSXDEY08D2 Modicon Premium Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eTSXDEY08D2\u003c\/strong\u003e is an 8-channel, 24 V DC discrete input module for the Modicon Premium programmable logic controller (PLC) platform. It acquires digital signals from field switches and 2-wire or 3-wire sensors, using electrically isolated inputs and screw-terminal connections for rack-mounted control cabinets.\u003c\/p\u003e\n\u003ch3\u003eSignal Thresholds and Sensor Compatibility\u003c\/h3\u003e\n\u003cp\u003eEach channel is rated for a nominal \u003cstrong\u003e24 V DC\u003c\/strong\u003e input with a \u003cstrong\u003e4 kOhm\u003c\/strong\u003e input impedance and \u003cstrong\u003e7 mA\u003c\/strong\u003e typical input current. State detection thresholds follow \u003cstrong\u003eEN\/IEC 61131-2\u003c\/strong\u003e criteria, requiring at least \u003cstrong\u003e11 V\u003c\/strong\u003e and \u003cstrong\u003e6.5 mA\u003c\/strong\u003e for a valid ON state and at most \u003cstrong\u003e5 V\u003c\/strong\u003e and \u003cstrong\u003e2 mA\u003c\/strong\u003e for an OFF state.\u003c\/p\u003e\n\u003cp\u003eCompatibility with 2-wire and 3-wire sensors depends on the \u003cstrong\u003e19-30 V DC\u003c\/strong\u003e sensor supply limit and maximum response time of \u003cstrong\u003e7 ms\u003c\/strong\u003e or less. Verify leakage current and voltage drop on 2-wire proximity sensors against the \u003cstrong\u003e2 mA\u003c\/strong\u003e OFF-state current limit and \u003cstrong\u003e11 V\u003c\/strong\u003e ON-state voltage threshold before wiring.\u003c\/p\u003e\n\u003ch3\u003eElectrical Isolation and Power Budget\u003c\/h3\u003e\n\u003cp\u003eDielectric strength is rated at \u003cstrong\u003e1500 V AC\u003c\/strong\u003e, helping separate field circuit transients from the backplane bus. Check rack power supply capacity against both \u003cstrong\u003e55 mA at 5 V DC\u003c\/strong\u003e and \u003cstrong\u003e80 mA at 24 V DC\u003c\/strong\u003e current draws.\u003c\/p\u003e\n\u003cp\u003eThermal planning should account for power dissipation of \u003cstrong\u003e1 W\u003c\/strong\u003e plus \u003cstrong\u003e0.15 W\u003c\/strong\u003e per active channel. The standard-format module weighs approximately \u003cstrong\u003e0.3 kg\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEY08D2 (also written as TSX-DEY-08D2 in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (Discrete Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e19-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e4 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Threshold\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 11 V, greater than or equal to 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Threshold\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 5 V, less than or equal to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e55 mA at 5 V DC; 80 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W + 0.15 W per active channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do 2-wire sensor leakage currents affect signal switching on the TSXDEY08D2? A: A valid OFF state requires current at or below \u003cstrong\u003e2 mA\u003c\/strong\u003e and voltage at or below \u003cstrong\u003e5 V\u003c\/strong\u003e. If a 2-wire sensor draws more than \u003cstrong\u003e2 mA\u003c\/strong\u003e in its off state, it can falsely register as ON, so check sensor leakage and load requirements before connecting.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply and thermal loads should I factor into panel design? A: Factor in \u003cstrong\u003e55 mA at 5 V DC\u003c\/strong\u003e and \u003cstrong\u003e80 mA at 24 V DC\u003c\/strong\u003e for module current consumption, plus \u003cstrong\u003e1 W\u003c\/strong\u003e base dissipation plus \u003cstrong\u003e0.15 W\u003c\/strong\u003e per active channel. Ensure the Modicon Premium rack and enclosure have sufficient power margin and heat dissipation for the active channel count.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TSXDEY08D2 match both TSXDEY08D2 and TSX-DEY-08D2 references? A: The provided资料 lists both TSXDEY08D2 and TSX-DEY-08D2 for the same Modicon Premium 8-channel 24 V DC digital input module. Confirm the exact catalog code on the physical module nameplate and wiring diagram during procurement and maintenance.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67970883780707,"sku":"TSXDEY08D2","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/335._2ff10a4e-3bda-424d-8b55-6865eb523e64.jpg?v=1795167906","url":"https:\/\/www.autocontrolglobal.com\/products\/schneider-electric-tsxdey08d2-modicon-premium-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}