{"product_id":"se4302t02-emerson-digital-output-charm-module-new-original-stock","title":"SE4302T02 Emerson Digital Output CHARM Module | New \u0026 Original Stock","description":"\u003ch1 data-path-to-node=\"0\"\u003eEmerson SE4302T02 KL3004X1-BA1 DO CHARM Module\u003c\/h1\u003e\n\u003cp data-path-to-node=\"1\"\u003eConfigured for galvanically isolated switching in Emerson DeltaV Electronic Marshalling platforms, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"103\"\u003eEmerson SE4302T02 KL3004X1-BA1\u003c\/b\u003e (\u003cb data-path-to-node=\"1\" data-index-in-node=\"135\"\u003eKL3004X1-BA1\u003c\/b\u003e DO 24 VDC Isolated CHARM) provides direct physical\/electrical execution. The component installs onto standard CHARM I\/O carriers, interfacing directly with inductive field loads operating between 4 V DC and 32 V DC. The solid-state hardware structure supports configurable momentary or continuous pulse operations, translating system backplane logic states into isolated physical loop control commands.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eSE4302T02 KL3004X1-BA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eUSA \/ Thailand\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e0.18 to 0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e107 x 41 x 105 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e22 mA maximum at 24 V DC (CHARM bus requirement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003eDigital Output (DO) Isolated CHARM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003e4 V DC to 32 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003eOutput Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003e1.0 A continuous, 2 A inrush (less than 100 ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,0,0\"\u003eOff-State Leakage Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,1,0\"\u003e1 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,0,0\"\u003eHeat Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,1,0\"\u003e0.46 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,0,0\"\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,1,0\"\u003eGalvanically isolated, factory tested to 1000 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,0,0\"\u003eField Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,1,0\"\u003e4 A current limiting with thermal shutoff and automatic reset\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,0,0\"\u003eContaminant Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,1,0\"\u003eISA-S71.04 Class G3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,16,0,0\"\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,16,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,17,0,0\"\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,17,1,0\"\u003e1 mm peak-to-peak (2 to 13.2 Hz), 0.7 g (13.2 to 150 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,18,0,0\"\u003eShock Tolerance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,18,1,0\"\u003e10 g half-sine wave, 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,19,0,0\"\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,19,1,0\"\u003eCE, UL, ATEX, IECEx, FM, UKEX (Zone 2 \/ Class I Div. 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol Coexistence\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe internal layout utilizes individual component-level barriers to preserve electrical integrity within high-density Electronic Marshalling enclosures.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eChannel-to-Channel Isolation:\u003c\/b\u003e Every CHARM slot maintains complete galvanic isolation factory tested to 1000 V DC. This setup confines electrical failures, ground differentials, and inductive voltage surges to a single field loop, preventing fault propagation across the system backplane or neighboring channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003e4-20 mA HART Loop Protocol Coexistence:\u003c\/b\u003e The solid-state output driver controls switching edge rates to minimize radio frequency generation. This layout suppresses electromagnetic induction into adjacent field wiring conduits containing sensitive 4-20 mA HART loop protocol signaling lines, maintaining low noise thresholds across the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eThermal Protection Integration:\u003c\/b\u003e Onboard active sensors scan for overcurrent conditions. When a field short circuit draws more than 4 A, the module initiates a thermal shutdown sequence, decoupling the load terminal until nominal junction temperatures are restored, followed by an automatic reset cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003eQ: How does the module handle the inductive energy spikes generated when switching off large solenoid coils?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: The solid-state output stage is designed to manage inductive loads with an inrush tolerance up to 2 A for durations less than 100 ms. The internal circuit components absorb and clamp the inductive back-EMF spikes within safe physical limits, eliminating the need for external flyback diodes across the field device terminals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: Can this specific digital output module be extracted and replaced while the sub-rack baseplate remains energized?\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eA: Yes. The mechanical and electrical interface allows single-channel hot-swap replacement under live plant conditions. Pulling or inserting the module from its backplane position does not introduce data corruption on the main terminal bus or voltage dips on adjacent CHARM slots.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eQ: Does the module monitor and report field-side open-circuit or short-circuit faults back to the DeltaV controller?\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eA: Yes. The hardware diagnostic matrix evaluates loop conditions against active load thresholds. Deviations such as overcurrent thermal shutdowns or out-of-bounds parameter drops trigger a fault register write, transmitting the error state upstream over the internal logic bus.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCarrier Insertion Mechanics:\u003c\/b\u003e Align the rear connector pins of the CHARM module perpendicularly with the designated slot on the I\/O baseplate module. Push the plastic housing firmly downward until the dual mechanical side latches catch and secure the unit to the DIN rail alignment matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eField Conductor Management:\u003c\/b\u003e Terminate field lines to the terminal blocks directly below the module. Strip wire insulation strictly to factory tolerances and ensure no uninsulated copper strands extend outside the screwless compression clamps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eGrounding Protocol:\u003c\/b\u003e Verify the mounting DIN rail establishes a low-impedance connection with the cabinet metalwork and the primary instrumentation earth system. Zone 2 and Class I Division 2 safety parameters require all structural grounding pathways to be validated prior to loop circuit activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eThermal Management Clearances:\u003c\/b\u003e Keep top and bottom convective cooling vents free of wire bundles or structural blocks. Maintain panel parameters to keep the internal micro-climate within the designated -40 to +70 deg C operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43840397836387,"sku":"SE4302T02","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/110.2_a0c72ccf-1469-40b5-825f-e586e719a63d.jpg?v=1763343795","url":"https:\/\/www.autocontrolglobal.com\/products\/se4302t02-emerson-digital-output-charm-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}