{"product_id":"se4601t07-emerson-charm-baseplate-new-original-stock","title":"SE4601T07 Emerson CHARM Baseplate | New \u0026 Original Stock","description":"\u003ch1 data-path-to-node=\"0\"\u003eEmerson SE4601T07 DeltaV Series\u003c\/h1\u003e\n\u003cp data-path-to-node=\"1\"\u003eConfigured for field-wiring termination, signal routing, and galvanic isolation in DeltaV S-Series I\/O subsystems, the \u003cb data-index-in-node=\"119\" data-path-to-node=\"1\"\u003eEmerson SE4601T07\u003c\/b\u003e (\u003cb data-index-in-node=\"138\" data-path-to-node=\"1\"\u003eSE4601T07\u003c\/b\u003e CHARM Baseplate) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eSE4601T07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eEmerson (DeltaV)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e0.10 kg net module weight \/ 3.00 kg nominal shipping footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003eApprox 125 x 41 x 105 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003eLogic derived from active S-Series backplane; external voltage range 18-30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eNominal Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003eMaximum Field Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003e35 VDC @ 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003eScrew-clamp terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,0,0\"\u003eWire Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,1,0\"\u003e12 to 24 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,0,0\"\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,1,0\"\u003eISA-S71.04 Class G3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,0,0\"\u003eShock \/ Vibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,1,0\"\u003e10 g, 11 ms half-sine \/ 1 mm (2-13.2 Hz), 0.7 g (13.2-150 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,0,0\"\u003eMechanical Keying\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,1,0\"\u003eRotary key mechanism for paired I\/O module matching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,0,0\"\u003eProtection Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,1,0\"\u003eII 3G Ex ec IIC Gc; Class I Division 2 Groups A-D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe hardware infrastructure serves as the physical routing terminal interface engineered to transfer 4-20 mA HART loop protocol parameters between analog instrumentation and active processing blocks. Galvanic isolation circuits embedded on the system-to-field interface intercept and arrest high-voltage electrical surges up to the rated limits. Channel-to-channel isolation metrics are maintained relative to the specific paired active logic card, preventing ground loop propagation across the discrete loops while establishing a clear, uninterrupted transmission pathway for high-frequency digital sub-carrier asset diagnostics.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: What are the distinct hot-swap restrictions for this baseplate assembly under live voltage conditions?\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eA: The physical removal or replacement of the passive baseplate assembly is restricted during active system operation. Hot-swapping is permitted only when no active S-Series I\/O card is installed in the slot, no field wiring is connected, and zero current pathways remain active on the termination block hardware.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eQ: How does the built-in mechanical rotary keying function affect card deployment?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: The baseplate incorporates an adjustable mechanical rotary keying dial. This indexing mechanism enforces correct I\/O module pairing, locking out mismatched active cards to prevent the insertion of conflicting voltage types into a slot pinned out and wired for specific instrument signals.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eSecure the baseplate assembly directly onto the standard S-Series I\/O carrier structure, confirming that the structural seating is flush and ground plane links are locked together.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eConfigure the mechanical rotary keying dial to match the alignment profile of the specific processing module assigned to that node position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eStrip and dress the 12 to 24 AWG field wiring conductors, securing them into the screw-clamp terminal blocks with standard industrial torque.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003eRoute all low-level signal lines through independent, grounded wire ways to isolate the data loops from high-voltage AC motor distribution lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003eGround the overall twisted-pair shields at a single end on the instrumentation grounding bar inside the enclosure panel to maintain isolation integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44212411301987,"sku":"SE4601T07","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/433._760dc969-d9a3-4a84-b2fc-df1e8ebd0736.jpg?v=1779698636","url":"https:\/\/www.autocontrolglobal.com\/products\/se4601t07-emerson-charm-baseplate-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}