SEPAM 1000+ S40 Schneider Electric Sepam Series 40 Protection Relay
SEPAM 1000+ S40 Schneider Electric Sepam Series 40 Protection Relay
SEPAM 1000+ S40 Schneider Electric Sepam Series 40 Protection Relay
/ 3

SEPAM 1000+ S40 Schneider Electric Sepam Series 40 Protection Relay

  • Manufacturer: Schneider

  • Part Number: SEPAM1000-S40

  • Condition:New with Original Package

  • Product Type: Ethernet Communication Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Schneider Electric SEPAM 1000+ S40 Digital Protection Relay

The Schneider Electric SEPAM 1000+ S40 (also referenced as SEPAM 1000 S40) is a multifunction digital protection relay in the PowerLogic Sepam Series 40 family for medium-voltage substation incomer and feeder protection. It combines current, voltage, and frequency protection elements with circuit breaker control, disturbance recording, and metering. Configured via SFT2841 software or its front user-machine interface (UMI), it integrates into switchgear panels with modular I/O and communication options.

Technical Specifications

Parameter Specification
Model SEPAM 1000+ S40 (SEPAM 1000 S40)
Brand Schneider Electric
Product Family PowerLogic Sepam
Product Series Series 40
Product Type Digital Protection Relay
Primary Application Medium-voltage substation incomer and feeder protection
Current Inputs 4
Voltage Inputs 3
Logic Inputs 10
Relay Outputs 8
Temperature Sensor Inputs Up to 16
Standard Communication 1 Modbus port (Modbus RTU)
Optional Communication Protocols IEC 60870-5-103, DNP3, Modbus TCP/IP, IEC 61850 (configuration-dependent)
User Interface Basic, Advanced, or Remote UMI
Configuration Software SFT2841
Setting Groups 2 groups
Logic Equation Editor 100 operators
Disturbance Recording Supported
Mounting Panel mounting

Protection Functions and Metering

The SEPAM 1000+ S40 measures phase and residual currents, line/phase voltages, frequency, active power, reactive power, and power factor across 4 current inputs and 3 voltage inputs. Two independent setting groups and a 100-operator logic equation editor adapt trip coordination to changing switchgear topologies.

Supported ANSI protection functions include:

  • Overcurrent and Earth Fault: Phase overcurrent (50/51), earth fault (50N/51N), sensitive earth fault (50G/51G), and negative sequence/unbalance (46).
  • Voltage Protection: Undervoltage (27/27S), overvoltage (59), neutral voltage displacement (59N), and negative sequence overvoltage (47).
  • Frequency and Breaker Control: Overfrequency (81H), underfrequency (81L), circuit breaker failure (50BF), automatic reclosing (79), and logic selectivity (68).

Hardware Configuration and Interfaces

Because hardware references vary by order code, exact auxiliary power supply ratings, UMI display type (Basic, Advanced, or Remote), and external communication modules must be verified against the specific base unit part number.

In full modular configurations, the unit supports 10 logic inputs, 8 relay outputs, and up to 16 temperature sensor inputs alongside its base Modbus RTU port. Optional protocol interfaces add IEC 60870-5-103, DNP3, Modbus TCP/IP, or IEC 61850 connectivity for SCADA integration.

Frequently Asked Questions

Q: What distinguishes the SEPAM 1000+ S40 from current-only protection relays? A: Unlike current-only models, the S40 incorporates 3 voltage inputs in addition to 4 current inputs, enabling voltage (27/59/59N/47), frequency (81H/81L), and power metering functions for substation incomers and feeders.

Q: How is the SEPAM 1000+ S40 configured and commissioned? A: Settings, protection curves, and the 100-operator logic equations are configured using Schneider Electric SFT2841 PC software or through the front-panel Basic, Advanced, or Remote UMI.

Q: Does every SEPAM 1000+ S40 unit ship with the same power supply and communication protocols? A: No. Auxiliary supply voltage, UMI type, and optional protocols (IEC 60870-5-103, DNP3, Modbus TCP/IP, or IEC 61850) depend on the specific hardware ordering reference, while 1 Modbus RTU port is standard.

You may also like