{"product_id":"sepam-1000-s40-schneider-electric-sepam-series-40-protection-relay","title":"SEPAM 1000+ S40 Schneider Electric Sepam Series 40 Protection Relay","description":"\u003ch2\u003eSchneider Electric SEPAM 1000+ S40 Digital Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric SEPAM 1000+ S40\u003c\/strong\u003e (also referenced as \u003cstrong\u003eSEPAM 1000 S40\u003c\/strong\u003e) is a multifunction digital protection relay in the PowerLogic Sepam Series 40 family for medium-voltage substation incomer and feeder protection. It combines current, voltage, and frequency protection elements with circuit breaker control, disturbance recording, and metering. Configured via SFT2841 software or its front user-machine interface (UMI), it integrates into switchgear panels with modular I\/O and communication options.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSEPAM 1000+ S40 (SEPAM 1000 S40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePowerLogic Sepam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSeries 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003eMedium-voltage substation incomer and feeder protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Inputs\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Communication\u003c\/td\u003e\n\u003ctd\u003e1 Modbus port (Modbus RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Communication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 60870-5-103, DNP3, Modbus TCP\/IP, IEC 61850 (configuration-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eBasic, Advanced, or Remote UMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eSFT2841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Groups\u003c\/td\u003e\n\u003ctd\u003e2 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Equation Editor\u003c\/td\u003e\n\u003ctd\u003e100 operators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisturbance Recording\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtection Functions and Metering\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEPAM 1000+ S40\u003c\/strong\u003e measures phase and residual currents, line\/phase voltages, frequency, active power, reactive power, and power factor across 4 current inputs and 3 voltage inputs. Two independent setting groups and a 100-operator logic equation editor adapt trip coordination to changing switchgear topologies.\u003c\/p\u003e\n\u003cp\u003eSupported ANSI protection functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent and Earth Fault:\u003c\/strong\u003e Phase overcurrent (50\/51), earth fault (50N\/51N), sensitive earth fault (50G\/51G), and negative sequence\/unbalance (46).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Protection:\u003c\/strong\u003e Undervoltage (27\/27S), overvoltage (59), neutral voltage displacement (59N), and negative sequence overvoltage (47).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency and Breaker Control:\u003c\/strong\u003e Overfrequency (81H), underfrequency (81L), circuit breaker failure (50BF), automatic reclosing (79), and logic selectivity (68).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Configuration and Interfaces\u003c\/h3\u003e\n\u003cp\u003eBecause hardware references vary by order code, exact auxiliary power supply ratings, UMI display type (Basic, Advanced, or Remote), and external communication modules must be verified against the specific base unit part number.\u003c\/p\u003e\n\u003cp\u003eIn full modular configurations, the unit supports 10 logic inputs, 8 relay outputs, and up to 16 temperature sensor inputs alongside its base Modbus RTU port. Optional protocol interfaces add IEC 60870-5-103, DNP3, Modbus TCP\/IP, or IEC 61850 connectivity for SCADA integration.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What distinguishes the SEPAM 1000+ S40 from current-only protection relays? A: Unlike current-only models, the S40 incorporates 3 voltage inputs in addition to 4 current inputs, enabling voltage (27\/59\/59N\/47), frequency (81H\/81L), and power metering functions for substation incomers and feeders.\u003c\/p\u003e\n\u003cp\u003eQ: How is the SEPAM 1000+ S40 configured and commissioned? A: Settings, protection curves, and the 100-operator logic equations are configured using Schneider Electric SFT2841 PC software or through the front-panel Basic, Advanced, or Remote UMI.\u003c\/p\u003e\n\u003cp\u003eQ: Does every SEPAM 1000+ S40 unit ship with the same power supply and communication protocols? A: No. Auxiliary supply voltage, UMI type, and optional protocols (IEC 60870-5-103, DNP3, Modbus TCP\/IP, or IEC 61850) depend on the specific hardware ordering reference, while 1 Modbus RTU port is standard.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67956960067683,"sku":"SEPAM1000-S40","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/323._f5450f30-6ff3-4f63-9a51-0a26edf37aa6.jpg?v=1795058080","url":"https:\/\/www.autocontrolglobal.com\/products\/sepam-1000-s40-schneider-electric-sepam-series-40-protection-relay","provider":"AutoControl Global","version":"1.0","type":"link"}