Siemens 6GK1411-2AB10 PROFINET AS-Interface Communication Gateways
Manufacturer: Siemens
-
Part Number: 6GK1411-2AB10
Condition:New with Original Package
Product Type: Communication Gateway
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Siemens 6GK1411-2AB10 IE/AS-i Link PN IO Gateway
Configured for bridging AS-Interface field networks to PROFINET IO control systems in industrial architectures, the Siemens 6GK1411-2AB10 (6GK1411-2AB10 IE/AS-i Link PN IO Gateway) provides direct physical/electrical execution. The hardware operates as a single AS-i master compliant with specification V3.0 profiles M3 and M4, transferring cyclic process image data and acyclic diagnostic parameters between connected actuator/sensor nodes and a primary PROFINET controller. Integrated LCD diagnostics and 24 VDC power terminals support immediate local status evaluation within standard IP20 control enclosures.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6GK1411-2AB10 |
| Brand | Siemens |
| Origin | Germany |
| Weight | 0.54 kg |
| Dimensions | 90 x 80 x 124 mm |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | 3.0 W at 24 VDC |
| Product Type | Communication Gateways |
| Function | AS-i to PROFINET IO gateway |
| AS-i Master Profile | M3, M4 (AS-i Spec V3.0) |
| AS-i Master Count | Single master |
| Field Interfaces | 1 x AS-Interface screw terminal block, 2 x RJ45 PROFINET ports |
| Diagnostics | Onboard LCD status display, LED indicators |
| Mounting | Standard 35 mm DIN rail |
| Protection Rating | IP20 |
| Lifecycle Status | Product cancelled |
Profinet Deterministic Networks and Firmware Integrity
The Siemens 6GK1411-2AB10 maintains deterministic real-time communication frames between field-level AS-i slaves and higher-tier PROFINET IO controllers over industrial Ethernet networks. By buffering physical bus cycles at the ASIC level, the module converts asynchronous AS-i slave address signals into synchronous Ethernet packets without introducing latency jitter. Furthermore, firmware flash compatibility supports seamless field updates to preserve network synchronization, while deterministic network handling ensures predictable update times for time-critical automation tasks.
Frequently Asked Questions
Q: How does the integrated LCD front display assist during hardware commissioning?
A: The front LCD display provides direct visual output of unconfigured AS-i slave addresses, duplicate address conflicts, and line fault conditions, which allows technicians to diagnose fieldbus errors without attaching an external engineering tool.
Q: What happens to the PROFINET bus connection if the 24 VDC auxiliary power supply fails?
A: A total loss of 24 VDC power drops the gateway offline, breaking communication with the PROFINET controller. To preserve network topology when configured in line structures, external switches or dual-port passthrough units must remain powered independently.
Q: Does the 6GK1411-2AB10 support automatic slave address assignment during module swap-out?
A: Yes, if a single defective AS-i slave is replaced with an identical unit of the same model and default address 0, the gateway automatically programs the new slave to the previous network address upon detection.
Field Installation Guidelines
Mount the gateway onto a standard 35 mm DIN rail inside an IP20-rated enclosure. Ensure that the mounting location provides adequate clearance around the top and bottom ventilation slots to maintain convective airflow across the 0 deg C to +60 deg C operational envelope.
Route the 2-wire AS-Interface ribbon cable using designated insulation-piercing or terminal block connections, maintaining strict separation from high-voltage AC lines. Connect the functional earth terminal directly to the enclosure ground bar using a short, low-impedance copper strap to mitigate high-frequency noise interference. Use shielded RJ45 CAT5e or CAT6 cables for PROFINET Ethernet connections and clamp the cable shields to ground near the entry point of the cabinet.