{"product_id":"siemens-6gk5004-1bd00-1ab2-scalance-xb004-1-ethernet-switchsiemens-6gk5004-1bd00-1ab2-scalance-xb004-1-ethernet-switch","title":"Siemens 6GK5004-1BD00-1AB2 SCALANCE XB004-1 Ethernet SwitchSiemens 6GK5004-1BD00-1AB2 SCALANCE XB004-1 Ethernet Switch","description":"\u003ch2\u003eSiemens 6GK5004-1BD00-1AB2 SCALANCE XB004-1 Industrial Ethernet Switch\u003c\/h2\u003e\n\u003cp\u003eConfigured for unmanaged packet forwarding and optical media conversion in Profinet \/ EtherNet\/IP deterministic networks, the \u003cstrong\u003eSiemens 6GK5004-1BD00-1AB2\u003c\/strong\u003e (\u003cstrong\u003eSCALANCE XB004-1\u003c\/strong\u003e Industrial Ethernet Switch) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK5004-1BD00-1AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eUnmanaged Industrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003e4 x RJ45 10\/100 Mbit\/s ports, 1 x SC multimode fiber port (100 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Method\u003c\/td\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC \/ VDC (supports redundant power input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e40 x 125 x 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Networking \u0026amp; Controller Integration\u003c\/h3\u003e\n\u003cp\u003eThe unmanaged switch processes raw frames using a store-and-forward switching architecture, maintaining backplane bus communication velocity across local Ethernet links. Field engineers deploy the 4 RJ45 ports and single SC fiber connector to scale local I\/O density while protecting optical lines against electromagnetic noise. Integrated firmware flash compatibility across SIMATIC automation devices enables transparent plug-and-play routing for Profinet traffic without requiring IP address assignment or managed network setup.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 6GK5004-1BD00-1AB2 support redundant power supply connections?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the terminal block provides dual power supply connections for 24 VAC \/ VDC inputs, allowing backup power supply integration to prevent downtime if one supply fails.\u003c\/p\u003e\n\u003cp\u003eQ: Can maintenance personnel hot-swap RJ45 or SC fiber cables during operation?\u003c\/p\u003e\n\u003cp\u003eA: Field technicians can plug and unplug Ethernet RJ45 cables and SC optical connectors during live system operation without resetting the hardware or affecting adjacent active ports.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting options are supported on the IP20 enclosure?\u003c\/p\u003e\n\u003cp\u003eA: The compact housing snaps directly onto a standard 35 mm DIN rail or mounts flat to an enclosure panel via built-in mounting holes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstallers must mount the IP20 housing inside a grounded control cabinet to protect electronic components from conductive dust and humidity.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSnap the rear mounting clip onto a standard 35 mm DIN rail until the spring lock latches securely into position.\u003c\/li\u003e\n\u003cli\u003eConnect dual 24 VDC or 24 VAC power wiring to the terminal block, ensuring tight screw clamping on both primary and redundant feed terminals.\u003c\/li\u003e\n\u003cli\u003eAttach shielded CAT5e or CAT6 Industrial Ethernet cables to the RJ45 ports, routing lines away from high-voltage motor drive power cables.\u003c\/li\u003e\n\u003cli\u003eInsert the multimode SC fiber connector into the optical port, keeping the minimum fiber bend radius greater than the cable manufacturer limit to avoid signal attenuation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43923237765219,"sku":"6GK5004-1BD00-1AB2","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/204.1_0cbf1fe5-8416-4ac5-95e6-d86986570889.jpg?v=1766975508","url":"https:\/\/www.autocontrolglobal.com\/products\/siemens-6gk5004-1bd00-1ab2-scalance-xb004-1-ethernet-switchsiemens-6gk5004-1bd00-1ab2-scalance-xb004-1-ethernet-switch","provider":"AutoControl Global","version":"1.0","type":"link"}